Home

/

Insights

/

Commercial fire safety

Guide

Fire Safety Regulations and Compliance Requirements for Commercial and Industrial Buildings

Learn the fundamentals of proper fire regulation compliance to safeguard your commercial and industrial buildings in the UK.

SmartMist Technical Team

Water mist and fire sprinkler specialists

July 28, 2025

6

Fire Safety Regulations and Compliance Requirements for Commercial and Industrial Buildings

Key takeaways

Fire safety regulations are critical for protecting lives, properties and businesses. Compliance with these regulations is not just a legal obligation but a moral duty. Property managers and business owners must take proactive steps to ensure their buildings are safe for occupants and meet stringent safety standards.

‍

Failure to comply can lead to fines, invalid insurance or imprisonment, while diligent adherence fosters trust, reduces risks and gives insurers the records they expect. Here’s what you need to know about safeguarding your commercial and industrial spaces for full fire safety in 2025 and beyond.

‍

Understanding the Regulatory Framework for Fire Safety

Three major UK-relevant regulations govern the frameworks that commercial property owners, developers and managers need to adhere to for full compliance:

Regulatory Reform (Fire Safety) Order 2005

This foundational legislation consolidates fire safety laws for non-domestic premises, placing responsibility on the “Responsible Person.” Key obligations include:

  • Conducting documented fire risk assessments.
  • Implementing safety measures such as alarms, suppression systems and evacuation plans.
  • Maintaining equipment to British Standards.
  • Training staff and reviewing safety procedures regularly.

Fire Safety (England) Regulations 2022

Introduced after the Grenfell Tower Inquiry, these regulations and measures enhance safety in multi-occupied and high-rise buildings:

  • Sharing building plans with the official fire services.
  • Installing wayfinding signage and secure information boxes.
  • Regular checks on lifts and firefighting equipment.

Approved Document B

This statutory guidance supports building regulations for non-dwelling premises, covering:

  • Fire resistance ratings for structural elements.
  • Requirements for escape routes and suppression systems.
  • Design considerations for changes to building use or layout.

Compliance Measures for Key Fire Safety Regulations

When commercial and industrial property owners understand the compliance measures that are in place, it’s easier to meet the required fire safety regulations. So, where to start?

‍

Fire Risk Assessments

A comprehensive fire risk assessment identifies hazards, evaluates safety measures and outlines actions to mitigate risks. Regular updates are essential, particularly when changes occur, such as installing new equipment or modifying building layouts.

‍

For example, a change of purpose, adding additional floors or extending your premises may render the previous system or safety policy void necessitating additional safety measures to enhance protection. Where the building is too far from a fire tender for safe escape, contains high-risk storage areas or retail space that forms part of a wider landlord or building development, thorough assessments need to be carried out to cover all possible fire risks.

Mandatory Equipment and Standards

Fire safety equipment must meet specific British Standards:

  • Fire alarms: BS 5839 (weekly tests, six-monthly servicing).
  • Portable extinguishers: BS 5306 (monthly checks, annual servicing).
  • Water mist systems: BS EN 14972-1 (inspection and maintenance as set out in the standard).
  • Emergency lighting: BS 5266 (monthly tests, annual duration tests).

The ‘Responsible Person’

The “Responsible Person” ensures compliance by setting policies, commissioning certified maintenance and maintaining records of safety activities. This accountability extends to implementing updates when regulations or building changes occur.

‍

The Role of Fire Suppression Systems in Ensuring Compliance

Fire suppression systems actively mitigate fire risks, protecting human lives and valuable property. Water mist systems are popular for high-heat environments, sprinklers are commonly found in standard risk areas and foam systems are often installed for flammable liquid storage.

‍

It’s important to note that BS EN 14972-1, the European water mist standard, alongside BS 8489-1:2016 for industrial and commercial systems, guides the design and maintenance of water mist systems, ensuring they meet hazard classifications and performance criteria. Designing to the right standard helps demonstrate compliance, including in establishments with saunas or kitchens.

‍

Addressing Fire Safety Challenges in Mixed-Use Developments

Mixed-use buildings present unique challenges, such as shared escape routes and varying occupancy types. Best practices include compartmentation to separate risk zones, independent suppression system controls for different occupancies and tailored evacuation plans for warehousing, retail, office and residential areas like hotels and hostels.

‍

Designs should be completed in line with appropriate risk hazards (OH1, OH2, LH) and should take into account the specific characteristics of mixed-use developments, such as ground floor retail combined with upper floor office spaces or residential tenant areas.

‍

The Importance of Staff Training in Fire Safety Compliance

Effective fire safety depends on well-trained staff who understand their roles during an emergency. Familiarity with evacuation procedures and exit routes, hands-on use of fire extinguishers and other safety equipment are essential.

‍

Safety measures hinge on recognising fire risks, reporting potential hazards, role-specific fire marshal instructions, well-briefed security teams and maintenance staff. Regular fire drills not only reinforce training but also help identify weaknesses in evacuation plans. Ensuring all personnel are prepared can significantly reduce response times and improve overall safety.

‍

Leveraging Technology for Improved Fire Safety Compliance

Modern technology can enhance fire safety and streamline compliance processes. The following commercial and industrial space investments make all the difference:

  • Smart fire detection systems: Advanced sensors can detect smoke, heat or gas more accurately, reducing false alarms and improving response times.
  • Integrated alarm and evacuation systems: Centralised systems notify all occupants simultaneously and provide clear instructions, especially useful in mixed-use developments.
  • Digital record-keeping: Cloud-based platforms help log maintenance schedules, inspection results and risk assessments, ensuring records are accessible during audits.
  • Remote monitoring: Fire suppression systems can be monitored remotely to detect faults or activation, allowing for faster intervention and maintenance scheduling.

Adopting these technologies not only ensures compliance but also demonstrates a forward-thinking approach to safety, often appealing to insurers and stakeholders.

‍

7 Practical Steps for Achieving Fire Safety Compliance

These seven easy steps provide an excellent guide for fire safety compliance in industrial and commercial spaces:

  1. Appoint a ‘Responsible Person’.
  2. Conduct a fire risk assessment and document findings.
  3. Develop and implement a fire safety plan.
  4. Install appropriate suppression and detection systems.
  5. Schedule regular maintenance and keep records.
  6. Train staff and conduct evacuation drills.
  7. Review safety measures regularly and update as needed.

Ensuring Safety and Compliance for Your Building

Fire safety is an ongoing responsibility that protects lives and investments. Adhere to regulations, maintain safety systems and consult with experts to create a secure environment for occupants.

‍

‍Contact SmartMist today for a fully compliant custom design in your commercial or industrial building.

‍

Download the PDF

Sources and references

About the author

SmartMist Technical Team

Water mist and fire sprinkler specialists

SmartMist Systems Ltd designs, installs and maintains water mist and fire sprinkler systems for homes and commercial buildings across England, Scotland and Wales. Its SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA.

Our accreditations and test evidence →

Keep reading

Related insights

All insights →

Talk to a specialist

Need advice for your building?

Send us your drawings or tell us about the project. We will recommend water mist, sprinklers or a combination, and explain the standards that apply.