Residential Fire Suppression


Water mist fire suppression for Passivhaus and low-energy homes. Designed around the airtight layer and services, with small pipework and minimal impact on the building's performance.

Fire tested to BS EN 14972-17:2025, the new UK standard for home water mist
Our residential water mist system has passed full-scale fire tests to BS EN 14972-17 at the FPA, a UKAS-accredited test house, making us one of the first UK companies to do so. It’s the standard that replaced BS 8458, which gives Building Control and approved inspectors confidence in your fire strategy.
Open-plan fire safety without the fire doors
Keep your open-plan kitchen, loft conversion or living space. Discreet DOME water mist nozzles provide an approved alternative to protected escape routes and can reduce the need for fire doors, subject to Building Control.
80% less water than a domestic sprinkler system
Our DOME Gen 2 nozzle uses around 8 litres per minute, compared with 45 to 60 for a typical sprinkler head. That means less water damage, smaller pipework, and in most homes no water storage tank.
British-designed, made and installed, with Building Control support
We design, manufacture, install and maintain every home water mist system in-house. Our compliance team works directly with Building Control to help get your project signed off.
Passive houses are built to tight tolerances. Every pipe that crosses the airtight layer needs planning, and services zones are often small. A fire suppression system has to fit that discipline, not fight it.
SmartMist's water mist system uses small-bore pipework and discreet heads, and can often run from the mains. We plan routes and penetrations with your architect and Passivhaus designer from the start, so protection doesn't compromise performance.

Two homes with the same floor area can need very different systems. These are the factors we look at first.
Pipes crossing the airtight layer need sealed, planned penetrations. Fewer, smaller pipes make that easier.
Pipework usually runs in a services void inside the airtight layer, alongside MVHR ducts.
Open-plan stairs and living spaces can need suppression to meet escape rules.
Many passive houses are timber frame, which affects how fire spreads and what Building Control asks for.
A mains-fed system avoids a tank and keeps plant inside the thermal envelope small.
Wales requires sprinklers in all new homes. Elsewhere, suppression is often an alternative to other measures.
In Wales, all new homes need one. In England and Scotland, it depends on the design: suppression is often used to allow open-plan layouts or where Building Control asks for it.
Sprinklers have been required in all new and converted houses and flats in Wales since January 2016.
Not required in most new houses, but suppression can support open-plan layouts or longer escape routes above 4.5m.
Required in new flats and social housing. For private houses, it's used where the design calls for it.
We install both, so we recommend whichever meets your design standard with the least water and disruption.
Water mist uses small-bore pipework and very little water, so fewer, smaller penetrations through the airtight layer and often no tank. Discreet heads suit clean Passivhaus interiors.
Explore residential water mist →Residential sprinklers to BS 9251 are an option where a larger water supply is available or specified. They need larger pipes and often a tank, which is harder to accommodate in a passive house.
Explore residential sprinklers →We join the project early, agree pipe routes and penetrations with your architect and Passivhaus designer, and coordinate with MVHR and other services.
First fix happens with the services, with the second fix and commissioning after decoration, and we provide everything Building Control needs.
Planned, sealed penetrations through the airtight layer.
Pipe routes coordinated with MVHR and electrics.
No tank where the mains can supply the flow.
Flush heads that suit clean interiors.
Which standard applies depends on the system, the building and, often, Building Control.
Building Regulations fire safety guidance for dwellings in England.
The European fire test standard for residential water mist. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.
The former UK residential water mist standard, withdrawn by BSI in July 2025 and replaced by BS EN 14972-17.
The European standard for water mist design, installation, inspection and maintenance. Every SmartMist water mist installation is designed to it.
Code of practice for sprinkler systems in domestic and residential occupancies.
This page explains typical requirements. It isn't a fire strategy or design specification.
Tested to BS EN 14972-17:2025 at the FPA
Our SmartMist DOME™ residential water mist system met the performance criteria of the open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory. Every installation is designed to BS EN 14972-1.

Passive House, Cornwall
SmartMist undertook a distinctive project in Cornwall, focusing on a Passive House – a building standard characterized by energy efficiency, reduced ecological footprint, and exceptional thermal comfort. Our task was to install an advanced fire suppression system, tailored to meet the unique requirements of this energy-efficient home.
Send drawings and the fire strategy. We'll confirm the likely system and design standard.
Layouts, hydraulic calculations and documents for Building Control and your warranty provider.
Planned around your build programme or residents.
Testing, handover pack and a maintenance plan from day one.
Residential systems need an annual service, plus the simple owner checks the design standard sets. We check pumps, valves and heads, and keep the records Building Control, landlords and insurers expect. We also maintain systems installed by other contractors.
Service & maintenance plans →Most projects are quoted after a drawing review.
Read our cost guide →Not if it's planned. Water mist uses small-bore pipework, so there are fewer, smaller penetrations, and we agree each one with your Passivhaus designer so it can be sealed properly.
Often not. Water mist uses very little water and can usually run from the mains, so there's no tank to fit inside the thermal envelope.
In Wales, all new homes need it. In England and Scotland, it depends on the design: suppression is often used to allow open-plan layouts, or where Building Control asks for it.
As early as possible, ideally at design stage, so pipe routes and penetrations are planned with the airtightness and services strategy.
No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.
Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.
Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.
BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.
No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.
No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).
A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.
Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.
Send what you have. These help us quote faster:
Or call 0330 113 5900