Residential Fire Suppression


Water mist fire suppression for modular and offsite-built homes, fitted in the factory and connected on site. Compact enough for tight module tolerances, and designed to meet devolved rules.

Fire tested to BS EN 14972-17:2025, the new UK standard for home water mist
Our residential water mist system has passed full-scale fire tests to BS EN 14972-17 at the FPA, a UKAS-accredited test house, making us one of the first UK companies to do so. It’s the standard that replaced BS 8458, which gives Building Control and approved inspectors confidence in your fire strategy.
Open-plan fire safety without the fire doors
Keep your open-plan kitchen, loft conversion or living space. Discreet DOME water mist nozzles provide an approved alternative to protected escape routes and can reduce the need for fire doors, subject to Building Control.
80% less water than a domestic sprinkler system
Our DOME Gen 2 nozzle uses around 8 litres per minute, compared with 45 to 60 for a typical sprinkler head. That means less water damage, smaller pipework, and in most homes no water storage tank.
British-designed, made and installed, with Building Control support
We design, manufacture, install and maintain every home water mist system in-house. Our compliance team works directly with Building Control to help get your project signed off.
Modular homes are built to tight dimensions, and services have to fit inside each module and connect cleanly on site. Fire suppression is easiest to get right when it's designed into the module, not added afterwards.
SmartMist supplies high-pressure water mist systems for modular and offsite homes. Our accredited installer can work alongside the factory team, so the system is fitted during construction of each unit.

Two homes with the same floor area can need very different systems. These are the factors we look at first.
Pipework and heads have to fit within tight, pre-designed module dimensions.
Most of the system is fitted in the factory, with connections made when modules are joined on site.
Wales requires sprinklers in all new homes. Scotland requires them in new flats and social housing.
Many modular homes are timber, which affects fire spread and what Building Control asks for.
Mains-fed systems avoid a tank in each home.
Warranty providers and Building Control need consistent design and test evidence across every unit.
It depends where you build. Wales requires sprinklers in all new homes, and Scotland in new flats and social housing. In England, most new houses don't need them unless the design does.
Sprinklers have been required in all new and converted houses and flats in Wales since January 2016.
Since March 2021, new flats, social housing and shared multi-occupancy buildings need automatic fire suppression.
Required in new blocks of flats 11m and over. In houses, suppression can support open-plan or longer escape routes.
We install both, so we recommend whichever meets your design standard with the least water and disruption.
Water mist uses small-bore pipework that fits inside tight module dimensions, and very little water, so many homes can run from the mains without a tank. Discreet heads suit finished interiors.
Explore residential water mist →Residential sprinklers to BS 9251 are an option where a larger water supply is available or specified. Larger pipes are harder to fit within module tolerances, which is one reason modular builders choose mist.
Explore residential sprinklers →We design the system with the module, agreeing pipe routes, head positions and connection points with your design team before production.
Installation happens in the factory alongside your production line, with final connections and commissioning on site.
Fitted during construction of each module.
Simple connections when modules are joined.
One design across house types for consistency.
No tank where the mains can supply the flow.
Which standard applies depends on the system, the building and, often, Building Control.
Building Regulations fire safety guidance for dwellings in England.
The European fire test standard for residential water mist. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.
The former UK residential water mist standard, withdrawn by BSI in July 2025 and replaced by BS EN 14972-17.
The European standard for water mist design, installation, inspection and maintenance. Every SmartMist water mist installation is designed to it.
Code of practice for sprinkler systems in domestic and residential occupancies.
This page explains typical requirements. It isn't a fire strategy or design specification.
Tested to BS EN 14972-17:2025 at the FPA
Our SmartMist DOME™ residential water mist system met the performance criteria of the open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory. Every installation is designed to BS EN 14972-1.

Modular Home, Wales
SmartMist embarked on an ambitious project in Wales, implementing a full-coverage fire suppression system in a new modular home development. This project was particularly significant due to the stringent fire safety regulations in Wales, which necessitate comprehensive fire protection in all new homes.
Send drawings and the fire strategy. We'll confirm the likely system and design standard.
Layouts, hydraulic calculations and documents for Building Control and your warranty provider.
Planned around your build programme or residents.
Testing, handover pack and a maintenance plan from day one.
Residential systems need an annual service, plus the simple owner checks the design standard sets. We check pumps, valves and heads, and keep the records Building Control, landlords and insurers expect. We also maintain systems installed by other contractors.
Service & maintenance plans →Most projects are quoted after a drawing review.
Read our cost guide →Yes. Our accredited installer can fit the system during construction of each unit at the factory, with final connections and commissioning on site.
Yes. All new homes in Wales, including modular homes, have needed sprinklers since January 2016.
Water mist uses small-bore pipework designed to fit tight module dimensions. We agree routes and head positions with your design team before production.
Usually not. Water mist uses very little water, so many homes can run from the mains.
No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.
Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.
Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.
BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.
No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.
No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).
A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.
Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.
Send what you have. These help us quote faster:
Or call 0330 113 5900