Residential Fire Suppression


Water mist fire suppression for houses in multiple occupation, from shared houses to large HMO conversions. Designed to support your licence and conversion plans, and installed around your tenants.

Fire tested to BS EN 14972-17:2025, the new UK standard for home water mist
Our residential water mist system has passed full-scale fire tests to BS EN 14972-17 at the FPA, a UKAS-accredited test house, making us one of the first UK companies to do so. It’s the standard that replaced BS 8458, which gives Building Control and approved inspectors confidence in your fire strategy.
Open-plan fire safety without the fire doors
Keep your open-plan kitchen, loft conversion or living space. Discreet DOME water mist nozzles provide an approved alternative to protected escape routes and can reduce the need for fire doors, subject to Building Control.
80% less water than a domestic sprinkler system
Our DOME Gen 2 nozzle uses around 8 litres per minute, compared with 45 to 60 for a typical sprinkler head. That means less water damage, smaller pipework, and in most homes no water storage tank.
British-designed, made and installed, with Building Control support
We design, manufacture, install and maintain every home water mist system in-house. Our compliance team works directly with Building Control to help get your project signed off.
HMOs bring more people, more cooking and more electrical equipment under one roof, often in buildings that were designed as single homes. A fire in one room can quickly block the shared escape route.
SmartMist designs and installs water mist systems for HMO landlords, developers and agents. Suppression controls a fire early, limits smoke in the shared stair and can support a conversion where other fire measures are difficult to achieve.

Two homes with the same floor area can need very different systems. These are the factors we look at first.
Most HMOs rely on a single shared stair. Keeping it clear of smoke is the priority.
Three or more storeys usually means stricter fire separation, detection and escape requirements.
Kitchens are the most common source of fires, and in HMOs they're shared by people who don't know each other.
Turning a house into an HMO can be a material change of use, which brings in Building Regulations.
Councils set fire safety conditions for HMO licences, often based on national LACoRS guidance.
Work often happens with tenants in place, so installs need to be quick and tidy.
Not usually by law, but councils and Building Control can accept suppression to offset other fire measures, for example in larger conversions or where the escape route is hard to protect.
Councils assess fire risk in HMOs and set licence conditions. Suppression can be accepted as a compensating measure.
National guidance councils use for HMO fire safety, covering detection, separation and escape.
A conversion to an HMO can need Building Control approval. Suppression can support the fire strategy.
We install both, so we recommend whichever meets your design standard with the least water and disruption.
Water mist uses a fraction of the water of a sprinkler, so less damage to rooms and the floors below, and less time empty after a fire. Small pipework and compact pumps make it easier to fit in existing houses.
Explore residential water mist →Residential sprinklers to BS 9251 are an option for larger HMOs or where the fire strategy specifies them. They usually need bigger pipes and often a tank, which is harder to fit in a converted house.
Explore residential sprinklers →We review the layout, the escape route and your council's or Building Control's requirements, then design a system that targets the risk, typically rooms, kitchens and the shared stair.
Installation is planned around tenants or the conversion programme, with commissioning and records for your licence file.
Coverage where fires usually start.
Protection for the shared stair and landings.
Pump units that fit in a cupboard or under stairs.
Commissioning certificates and service records.
Which standard applies depends on the system, the building and, often, Building Control.
National guidance councils use for fire safety in HMOs.
Building Regulations fire safety guidance for dwellings in England.
The European fire test standard for residential water mist. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.
The former UK residential water mist standard, withdrawn by BSI in July 2025 and replaced by BS EN 14972-17.
The European standard for water mist design, installation, inspection and maintenance. Every SmartMist water mist installation is designed to it.
Code of practice for sprinkler systems in domestic and residential occupancies.
This page explains typical requirements. It isn't a fire strategy or design specification.
Tested to BS EN 14972-17:2025 at the FPA
Our SmartMist DOME™ residential water mist system met the performance criteria of the open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory. Every installation is designed to BS EN 14972-1.
.webp)
HMO, London
Residential space in London is constantly in demand, so when you have an opportunity to maximise your developments and convert your property into something such as an HMO, it is hard to see the negatives. With that being said, new rules and regulations mean that in some cases, you would be required to add additional protection measures, such as interlinked fire alarm systems, 30- or 60-minute fire rated doors and supplementary fire suppression systems to ensure adequate protection.
Send drawings and the fire strategy. We'll confirm the likely system and design standard.
Layouts, hydraulic calculations and documents for Building Control and your warranty provider.
Planned around your build programme or residents.
Testing, handover pack and a maintenance plan from day one.
Residential systems need an annual service, plus the simple owner checks the design standard sets. We check pumps, valves and heads, and keep the records Building Control, landlords and insurers expect. We also maintain systems installed by other contractors.
Service & maintenance plans →Most projects are quoted after a drawing review.
Read our cost guide →Not usually by law. But councils and Building Control can accept suppression as a compensating measure, for example where the shared escape route is hard to protect or in larger conversions.
It can. Councils set fire safety conditions for licences, and suppression is one way to meet them where other measures are difficult. Check with your council's housing team, and we'll design to their requirements.
Yes. Small-bore pipework and compact pumps mean less disruption, and we plan access with you and your tenants.
Often, because it uses smaller pipes and usually no tank, which cuts installation time in an existing house. We'll compare both if you're unsure.
No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.
Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.
Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.
BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.
No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.
No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).
A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.
Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.
Send what you have. These help us quote faster:
Or call 0330 113 5900