Home

›

Residential

›

Care Homes

Residential fire suppression

Care Home Fire Suppression Systems

Sprinkler and water mist systems for care and nursing homes. Designed for residents who need help to escape, installed around their routines, and serviced for the life of the building.

✓ Water mist & sprinklers
✓ Design to commissioning
✓ UK-wide installation
Care Home Fire Suppression Systems

Fire tested to BS EN 14972-17:2025, the new UK standard for home water mist

Our residential water mist system has passed full-scale fire tests to BS EN 14972-17 at the FPA, a UKAS-accredited test house, making us one of the first UK companies to do so. It’s the standard that replaced BS 8458, which gives Building Control and approved inspectors confidence in your fire strategy.

Open-plan fire safety without the fire doors

Keep your open-plan kitchen, loft conversion or living space. Discreet DOME water mist nozzles provide an approved alternative to protected escape routes and can reduce the need for fire doors, subject to Building Control.

80% less water than a domestic sprinkler system

Our DOME Gen 2 nozzle uses around 8 litres per minute, compared with 45 to 60 for a typical sprinkler head. That means less water damage, smaller pipework, and in most homes no water storage tank.

British-designed, made and installed, with Building Control support

We design, manufacture, install and maintain every home water mist system in-house. Our compliance team works directly with Building Control to help get your project signed off.

OverviewRisk factorsRegulationsMist or sprinklerDesignStandardsMaintenance & costFAQsEnquire
Residential fire protection

Fire protection for residents who need more time

Many care home residents have limited mobility or cognitive impairment and depend on staff to move them to safety. Suppression controls a fire where it starts, limits smoke and gives staff time to carry out a phased evacuation.

SmartMist designs, installs and maintains sprinkler and water mist systems for care and nursing homes. Water mist uses much less water than sprinklers, can often run from smaller supplies, and its small pipework is easier to retrofit into occupied homes.

  • New care homes and extensions
  • Retrofits in occupied homes
  • Bedrooms, lounges, kitchens and escape routes
See all residential fire suppression →
Fire protection for residents who need more time
What shapes the design

What shapes fire protection in a care home

Two homes with the same floor area can need very different systems. These are the factors we look at first.

Dependent residents

Residents may need staff to help them escape. The fire strategy often relies on moving them to another compartment rather than outside.

Night-time staffing

Fewer staff at night means early fire control matters most when evacuation is slowest.

Occupied buildings

Care homes can't close. Retrofits are planned room by room around residents' routines.

Kitchens and laundries

Higher-risk rooms may need different heads or separate protection.

Water supply

Sprinklers may need a tank and pump. Water mist can reduce tank size or run from the mains.

New build rules

In England, new care homes now need sprinklers whatever their height.

Requirements

Do care homes need sprinklers?

New care homes in England need sprinklers whatever their height, under Approved Document B from 2 March 2025. Scotland and Wales already require suppression in new care homes.

England

Approved Document B

From 2 March 2025, new care homes should have sprinklers whatever their height, with transitional rules for projects already underway.

Scotland & Wales

Devolved rules

Scotland requires automatic fire suppression in new care homes. Wales has required sprinklers in new and converted care homes since 2014.

Fire safety law

Fire Safety Order 2005

Existing homes need a suitable fire risk assessment, which may recommend suppression for higher-risk residents or layouts.

Choosing a system

Water mist or fire sprinklers?

We install both, so we recommend whichever meets your design standard with the least water and disruption.

Water mist

Less water, often no tank

Water mist uses a fraction of the water of a sprinkler, which limits damage and disruption after activation. Small-bore pipework and compact pumps suit retrofits, and smaller systems can often run from the mains without a large tank.

Explore residential water mist →
Fire sprinklers

The established, widely specified route

Sprinklers to BS 9251 are the established route for care homes and the one Approved Document B refers to. We design and install them for new homes and extensions, with tank and pump sets where the mains can't supply the flow.

Explore residential sprinklers →
Mist and sprinklers aren't interchangeable in every building. We confirm the design standard with Building Control and your fire engineer before design, then recommend the system that meets it.
Design & installation

Designed with the building, installed around residents

We design with your fire strategy, working with your fire engineer and Building Control on new homes, and with your fire risk assessor on existing ones. Systems link to the fire alarm so staff know where a fire is.

In occupied homes we work room by room, agree times with the manager and keep residents' routines as normal as possible.

Send your drawings

Bedrooms & lounges

Coverage in every room, with heads that suit a homely setting.

Kitchens & laundries

Protection matched to higher-risk rooms.

Alarm integration

Links to the fire alarm and staff call systems.

Room-by-room install

Work planned around residents and care routines.

Standards & compliance

Standards for care home fire suppression

Which standard applies depends on the system, the building and, often, Building Control.

Standard
Relevance
Status

Approved Document B Vol 2

Sprinklers in all new care homes in England from 2 March 2025.

Current

BS 9251:2021

Code of practice for sprinkler systems in domestic and residential occupancies.

Current

BS EN 14972-17:2025

The European fire test standard for residential water mist. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.

Tested

BS 8458:2015

The former UK residential water mist standard, withdrawn by BSI in July 2025 and replaced by BS EN 14972-17.

Withdrawn

BS EN 14972-1

The European standard for water mist design, installation, inspection and maintenance. Every SmartMist water mist installation is designed to it.

Designed to

Fire Safety Order 2005

Requires a suitable fire risk assessment for existing care homes.

Current

This page explains typical requirements. It isn't a fire strategy or design specification.

Certification & accreditation

ISO 9001:2015
Quality management
SafeContractor
Health and safety accreditation

Tested to BS EN 14972-17:2025 at the FPA

Our SmartMist DOME™ residential water mist system met the performance criteria of the open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory. Every installation is designed to BS EN 14972-1.

See all our accreditations →

Recent Clients

How we work

From drawings to handover

01

Review

Send drawings and the fire strategy. We'll confirm the likely system and design standard.

02

Design

Layouts, hydraulic calculations and documents for Building Control and your warranty provider.

03

Install

Planned around your build programme or residents.

04

Commission

Testing, handover pack and a maintenance plan from day one.

Aftercare

Servicing, including systems we didn't install

Residential systems need an annual service, plus the simple owner checks the design standard sets. We check pumps, valves and heads, and keep the records Building Control, landlords and insurers expect. We also maintain systems installed by other contractors.

Service & maintenance plans →
Cost

What affects the price

  • Number of beds and floors: sets head count and water demand
  • New build or retrofit: occupied homes need room-by-room work
  • Mist or sprinkler: changes tank, pump and pipe size
  • Kitchens and laundries: may need different protection
  • Water supply: mains-fed or tank and pump
  • Alarm integration: links to fire alarm and call systems

Most projects are quoted after a drawing review.

Read our cost guide →
Guides

Regulations and guidance

FAQs

Care home fire suppression FAQs

Do care homes need sprinklers?

New care homes in England need sprinklers whatever their height, under Approved Document B from 2 March 2025. Scotland and Wales already require suppression in new care homes. Existing homes aren't automatically required to retrofit, but the fire risk assessment may recommend it.

Can water mist be used in a care home instead of sprinklers?

Often, yes, where Building Control and your fire engineer accept it as meeting the same objectives. We confirm the design standard with them before design starts.

Can you install a system without moving residents out?

Yes. We work room by room, agree times with the home manager and keep disruption to residents' routines to a minimum.

How does suppression help with evacuation?

It controls the fire where it starts and limits smoke, which gives staff more time to move residents to a safe compartment or out of the building.

Is BS 8458 still current for water mist systems?

No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.

Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.

Are SmartMist residential water mist systems independently tested?

Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.

BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.

Will all the nozzles activate in my property in the event of a fire?

No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.

Does smoke caused by burning food trigger the water mist nozzle?

No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).

A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.

Are misting fire suppression systems safe for electronics and furniture?

Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.

Get a quote

Have a project in mind?

Send what you have. These help us quote faster:

  1. Floor plans
  2. Number of beds and storeys
  3. New build, extension or existing home
  4. Fire strategy or fire risk assessment
  5. Resident dependency and evacuation approach
  6. Water supply and plant space
  7. Preferred working times
  8. Registered manager contact

Or call 0330 113 5900

Upload Floor Plan Drag and drop files here or click to choose
No file chosen
Should be Empty:
Related

Other residential sectors

No items found.
Get a quote

Call Us