Residential Fire Suppression


Sprinkler and water mist systems for high-rise residential blocks, from new builds to occupied retrofits. Designed with your fire engineer, installed flat by flat, and maintained for the life of the building.
.avif)
Fire tested to BS EN 14972-17:2025, the new UK standard for home water mist
Our residential water mist system has passed full-scale fire tests to BS EN 14972-17 at the FPA, a UKAS-accredited test house, making us one of the first UK companies to do so. It’s the standard that replaced BS 8458, which gives Building Control and approved inspectors confidence in your fire strategy.
Open-plan fire safety without the fire doors
Keep your open-plan kitchen, loft conversion or living space. Discreet DOME water mist nozzles provide an approved alternative to protected escape routes and can reduce the need for fire doors, subject to Building Control.
80% less water than a domestic sprinkler system
Our DOME Gen 2 nozzle uses around 8 litres per minute, compared with 45 to 60 for a typical sprinkler head. That means less water damage, smaller pipework, and in most homes no water storage tank.
British-designed, made and installed, with Building Control support
We design, manufacture, install and maintain every home water mist system in-house. Our compliance team works directly with Building Control to help get your project signed off.
In a tower block, a fire in one flat can put every resident above it at risk. Suppression controls the fire where it starts, limits smoke in shared escape routes and gives the fire service time to work.
SmartMist designs, installs and maintains water mist and sprinkler systems for apartment and tower blocks across the UK. We work with developers, architects and fire engineers on new buildings, and with landlords and managing agents on retrofits in occupied blocks.

Two homes with the same floor area can need very different systems. These are the factors we look at first.
In England, new blocks of flats with a storey 11m or more above ground need sprinklers throughout. Blocks of 18m or 7 storeys and above are higher-risk buildings under the Building Safety Act.
Most blocks rely on residents staying in their flat unless the fire is in it. Suppression supports that strategy by controlling fires early.
Tall buildings often need a tank and pump set. Low-flow water mist can reduce tank size and plant space.
Retrofits happen around residents. Small-bore pipework and flat-by-flat programmes keep disruption down.
Corridors, lobbies and bin stores need protecting as well as flats, and may need different heads or zoning.
Higher-risk buildings need accurate, up-to-date records of the system, from design through every service.
New blocks of flats in England with a storey 11m or more above ground need sprinklers throughout. In Scotland and Wales, all new flats need automatic fire suppression, whatever the height.
New blocks of flats with a top storey 11m or more above ground should have sprinklers throughout, in every flat.
Blocks of 18m or 7 storeys and above need Building Safety Regulator approval before work starts, and a golden thread of information.
Scotland requires fire suppression in all new flats. Wales has required sprinklers in all new and converted homes since 2016.
We install both, so we recommend whichever meets your design standard with the least water and disruption.
Water mist uses a fraction of the water of a sprinkler, which can mean a smaller tank, less plant space and less damage to the flats below. Small-bore pipework is easier to route in occupied blocks, and options include individual pump units per flat or a whole-building system.
Explore residential water mist →Residential sprinklers to BS 9251 are the established route for tall blocks, and the one many fire strategies specify. We design and install them for new buildings, and retrofit them into existing blocks with a tank and pump set where the mains can't supply the flow.
Explore residential sprinklers →Tower block systems are designed with the fire strategy, not around it. We agree head layouts, water supply and zoning with your fire engineer, architect and Building Control, and provide the documents higher-risk building approvals need.
For occupied blocks we plan the work flat by flat, keep residents informed and leave each home tidy at the end of the day.
Coverage for flats, corridors, lobbies and bin stores.
Tank and pump sets sized to the building's demand.
Zone valves and links to the fire alarm and building management.
Design and service records for the golden thread.
Which standard applies depends on the system, the building and, often, Building Control.
Sprinklers throughout new blocks of flats with a storey 11m or more above ground.
Code of practice for sprinkler systems in domestic and residential occupancies.
Fire safety in the design, management and use of residential buildings.
The European standard for water mist design, installation, inspection and maintenance. Every SmartMist water mist installation is designed to it.
The European fire test standard for residential water mist. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.
The former UK residential water mist standard, withdrawn by BSI in July 2025 and replaced by BS EN 14972-17.
Regulator approval and golden thread for blocks of 18m or 7 storeys and above.
This page explains typical requirements. It isn't a fire strategy or design specification.
Tested to BS EN 14972-17:2025 at the FPA
Our SmartMist DOME™ residential water mist system met the performance criteria of the open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory. Every installation is designed to BS EN 14972-1.

Apartment Block Conversion, Norwich
Client: Private Investment Company
Location: Norwich, UK
Project Duration: 18 months (First Fix to Commissioning)
Team on Site: Dedicated Project Manager on-site for 4 months
Send drawings and the fire strategy. We'll confirm the likely system and design standard.
Layouts, hydraulic calculations and documents for Building Control and your warranty provider.
Planned around your build programme or residents.
Testing, handover pack and a maintenance plan from day one.
Residential systems need an annual service, plus the simple owner checks the design standard sets. We check pumps, valves and heads, and keep the records Building Control, landlords and insurers expect. We also maintain systems installed by other contractors.
Service & maintenance plans →Most projects are quoted after a drawing review.
Read our cost guide →New blocks of flats in England with a storey 11m or more above ground need sprinklers throughout, under Approved Document B. In Scotland and Wales, all new flats need automatic fire suppression whatever the height. For existing blocks, a retrofit is usually driven by the fire risk assessment or fire strategy.
Often, yes, but it depends on the fire strategy. Water mist can meet the same objectives with far less water, and Building Control and fire engineers increasingly accept it. We confirm the design standard with them before design starts.
Yes. We work flat by flat, using small-bore pipework where we can, and plan access with your managing agent so each home is left tidy at the end of the day.
Blocks of 18m or 7 storeys and above need Building Safety Regulator approval before work starts, and accurate records of the system for the golden thread. We provide design and service records in a format that supports this.
No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.
Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.
Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.
BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.
No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.
No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).
A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.
Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.