Residential

Water Mist & Fire Sprinkler Systems

phone icon

Speak to our team today

0330 113 5900

Expert advice. Bespoke solutions. No obligation.

Cost effective water mist and fire sprinkler solutions

Residential Fire Suppression System

Reliable & Compliant Systems for Homes of All Sizes

At SmartMist, we specialise in the installation of high-quality residential water mist and fire sprinkler systems designed to protect lives and property. Fire sprinklers and mist are a critical safety measure, providing rapid suppression of fires before they can spread, reducing damage and giving occupants valuable time to escape.

Unlike some providers who only take on large-scale projects, we believe every home deserves expert fire protection-no matter the size or complexity of the job.

Whether you need a single sprinkler for a loft conversion, a system for a new build, or comprehensive coverage for a large residential complex, we can design and install a solution that meets your needs.

We operate across England, Wales, and Scotland, ensuring reliable and compliant fire suppression solutions wherever you are.

Industry Leading

SmartMist has been at the forefront of residential water mist fire suppression in the UK for nearly a decade, building a reputation for technical expertise, innovation and independently tested performance. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory.

British Engineering

SmartMist designs and manufactures its own residential water mist nozzles in the UK, supported by ISO 9001 certification covering the design, manufacture, assembly and supply of water mist and sprinkler fire suppression nozzles.

Combined with our nationwide network of approved installers, we bring British engineering, technical expertise and professional installation together to protect homes across the UK.

Water Mist & Sprinkler Technology

While our core focus is on residential mist suppression systems, we also offer a complete range of sprinkler systems, meaning we can give clear, impartial guidance on the best approach for your property. In both mist and sprinkler sectors, we’ve built an unrivalled reputation for product quality, installation standards, and aftercare.

Our clients include architects, developers, building control specialists, and private homeowners who want nothing left to chance when it comes to fire protection.

Expertise & Innovation

Our experienced team combines technical design expertise with practical site knowledge, supported by SafeContractor accreditation and a commitment to safe, professional working practices. From initial design through to installation, commissioning and ongoing maintenance, SmartMist provides complete project support.

SmartMist’s in-house team combines design expertise with practical site knowledge, so we don’t just send out equipment, we help you integrate it, install it and commission it properly. And once it’s in, we stay involved, offering tailored maintenance and servicing to ensure your system remains compliant and in full working order.

We’re constantly evolving to meet emerging fire safety risks in the home. One of our latest innovations is a dedicated mist suppression solution specifically designed to protect against lithium battery fires, an increasing concern in today’s residential environments. From e-bike chargers to home energy storage systems, these everyday technologies carry unique fire risks.

Our system has been tested with real-world data to demonstrate effective suppression in these scenarios, offering an extra layer of safety for modern homes. It’s this kind of forward-thinking, backed by a decade of experience, that keeps SmartMist at the forefront of residential fire protection in the UK.

If you’re looking for a long-term fire protection partner who understands the full picture, from compliance and certification to aesthetics and installation, SmartMist is here to help. We’ll guide you through the process with clear advice, honest timelines, and reliable results.

RESIDENTIAL MIST SYSTEM INSTALLATION

How It Works & Costs

Our Installation Process‍

01

Consultation Assessment

We begin by understanding your property and safety needs.

02

Free System Design

Our engineers produce a detailed, tailored design, at no cost.

03

Your Approval

You review and approve the plan before we move forward.

04

Expert Installation & Commissioning

Installed by trained SmartMist professionals to exacting standards.

05

Ongoing Servicing

Flexible maintenance plans keep your system in peak condition.

Frequently Asked Questions

General

General

What fire safety standards do SmartMist systems meet?

Our residential sprinkler systems are designed to BS 9251. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1.

BS EN 14972-17:2025
Tested at the FPA

BS EN 14972-1
Designed to

ISO 9001
Certified quality management*

SafeContractor
Health & safety accredited

*ISO 9001 scope: design, manufacture, assembly and supply of water mist and sprinkler fire suppression nozzles.

See all our accreditations, certificate numbers and expiry dates.

Will I need a storage tank or booster pump?

It depends on your mains water supply's pressure and flow. Sprinklers generally need higher flow rates, often necessitating a booster pump or tank. Mist systems typically require less water and may operate directly from mains supply. We'll perform a thorough survey to determine your specific requirements.

‍

How often do these systems require servicing?

Both mist and sprinkler systems require annual servicing to ensure optimal performance and compliance with safety standards. We offer convenient, cost-effective maintenance plans tailored to your system and building.

How disruptive is the installation?

Installation disruption is minimal, especially if integrated during construction or refurbishment phases. We coordinate closely with your construction or refurbishment schedule, aiming for efficient installation with minimal inconvenience.

Do you handle the installation process directly?

Yes. All installations are carried out by qualified SmartMist engineers or our carefully vetted installation partners. We manage the entire process, including design, installation, testing, and commissioning, ensuring seamless project delivery.

Do your systems comply with current fire safety regulations?

Every system we install is designed for the project's fire strategy and agreed with Building Control before work starts. Our residential sprinklers are designed to BS 9251.

Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1.

Are you impartial regarding mist and sprinkler systems?

Yes, we offer both mist and sprinkler systems and have no inherent preference. Our recommendation is always based purely on what best suits your specific project, budget, and compliance requirements.

How do I know which system, sprinklers or mist, is right for my property?

It depends on your property's size, occupancy type, available water supply, and specific compliance requirements. We'll assess your property thoroughly to advise the most appropriate solution, ensuring maximum safety, efficiency, and compliance.

What’s the difference between fire sprinklers and mist systems?

Sprinklers release larger water droplets at a higher volume, effectively soaking a fire and surrounding area. Mist systems use fine droplets at lower volumes, rapidly cooling fires and reducing smoke. Both systems are highly effective, with suitability depending on your building and project requirements.

Fire Sprinkler

What happens if a fire sprinkler malfunctions?

Fire sprinkler malfunctions are rare, but potential issues include leaks, corrosion, or accidental discharge. To prevent malfunctions, systems should be routinely inspected, and pressure and valve controls checked to ensure they operate correctly. Only heat activates sprinklers, meaning false alarms due to smoke or steam are extremely unlikely.

Do I need a fire sprinkler system in my home?

While not always a legal requirement, fire sprinkler systems are often recommended or requested by building control, especially in multi-storey homes, loft conversions, or properties with limited escape routes. They’re a proactive way to protect your home and loved ones.

What standards do your sprinkler systems comply with?

Our installations meet BS 9251 for residential, BS EN 12845 for commercial and industrial buildings, and relevant EN standards. We also work to any project-specific compliance requirements.

How do fire sprinklers work in a residential setting?

Each sprinkler head operates independently and only activates in response to high heat from a fire in that specific area. This ensures rapid localised suppression without unnecessarily soaking other parts of your home.

Will the sprinkler system go off accidentally?

No. Sprinkler heads are designed to activate only when exposed to fire-level heat, usually around 68°C or higher. They will not activate due to smoke, burnt toast, or false alarms.

How much water do the sprinklers use?

Residential fire sprinklers are designed to use minimal water, typically far less than the amount used by fire services. This helps limit fire damage while also reducing water-related damage to your home.

Can sprinklers be retrofitted in existing homes?

Yes. We regularly install sprinkler systems in existing homes, extensions, and loft conversions. Our team will work with you to design a discreet and efficient system tailored to your property layout.

Will a sprinkler system spoil the look of my home?

Not at all. Modern residential sprinkler heads are compact and can be colour-matched or concealed within ceilings. We always aim for a clean, unobtrusive finish that blends seamlessly with your interior.

What regulations do your sprinkler systems comply with?

All SmartMist residential sprinkler systems are designed and installed to meet BS 9251 and comply with BS 9991 fire safety guidance for dwellings. This ensures both compliance and peace of mind.

What is the difference between domestic and residential sprinklers?

The key difference is capacity and coverage.

  • Domestic sprinkler systems are designed for single dwellings and have a lower water demand.
  • Residential sprinkler systems cover larger properties, such as apartment blocks and care homes, offering higher protection levels.

Water Mist

What is water mist?

The Building Research Establishment (BRE) defines water mist as a fixed fire protection system that uses water to control, suppress or extinguish a fire. Compared with traditional sprinklers, water mist is easier to install, which makes it well suited to new builds and to retrofitting existing buildings.

Is BS 8458 still current for water mist systems?

No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.

Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.

Are SmartMist residential water mist systems independently tested?

Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.

BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.

Is SmartMist an accredited fire suppression company?

Yes. SmartMist holds ISO 9001 certification for the design, manufacture, assembly and supply of water mist and sprinkler fire suppression nozzles. We are also SafeContractor accredited, demonstrating our commitment to quality management and safe working practices. Combined with our independently tested water mist systems, these credentials provide reassurance to homeowners, developers and building professionals.

See all our accreditations and how to verify them.

How many nozzles do I need to protect my space?

  • One nozzle protects an area of 4m x 4m (16m²), there must be a maximum of 2m from a wall and there must be a maximum of 4m between nozzles.
  • We always recommend that any project is sent to either Smart Mist or one of our accredited installers who will review the property plans and provide a design suitable for presentation to your Building Control department for approval.

Will all the nozzles activate in my property in the event of a fire?

No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.

Does smoke caused by burning food trigger the water mist nozzle?

No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).

A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.

Where can SmartMist water mist be used?

SmartMist residential water mist is designed for homes and residential buildings. Our SmartMist DOME™ residential water mist system was fire tested to BS EN 14972-17, the European standard for residential occupancies, at 3.5 m room height. Typical uses include:

  • Houses, flats and maisonettes
  • Houses in multiple occupation (HMOs)
  • Care homes and sheltered housing
  • Bed and breakfasts and small hotels
  • Hotel bedrooms and corridors
  • Hostels

We confirm the right system for your building with your fire strategy and Building Control before design starts. For commercial buildings, see our commercial fire suppression pages.

Are misting fire suppression systems safe for electronics and furniture?

Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.

Do misting systems require a dedicated water supply?

Some misting systems connect directly to the mains, while others need a separate water tank depending on the property’s requirements.

How often do residential misting systems need servicing?

Regular maintenance is recommended annually to ensure the system remains in optimal working condition.

Can a misting system be retrofitted into an existing home?

Yes, misting systems can be installed in existing buildings with minimal disruption, though installation may require structural assessment.

Does a SmartMist system have to be installed by an accredited installer?

Yes. The SmartMist system must be installed, commissioned and maintained by a SmartMist accredited installer to meet the requirements of the standard. All SmartMist approved installers are third-party accredited and hold the necessary insurances.

Does the high pressure hose need to be installed behind a fire rated barrier?

Yes. The flexible tubing or high pressure hose used by SmartMist must be installed behind a fire rated barrier.

Where a fire barrier cannot be provided, such as on a concrete ceiling, 316 stainless steel rigid pipework should be used.

Can high pressure water mist be a danger to people?

No. The force of the spray drops off quickly after it leaves the nozzle, so the mist droplets are generally harmless one metre away from the nozzle.

Can water mist nozzles get clogged in hard water areas?

Hard water has a high mineral content, mostly calcium and magnesium carbonates, bicarbonates and sulphates. These deposits normally build up where water is flowing. The water in a mist system is static and held at low pressure, so deposits do not form at the nozzles.

Can water mist nozzles get clogged by corrosion?

The nozzles and other system components are made from corrosion-resistant materials. SmartMist heads go through a process that protects against corrosion.

Filters are normally fitted at the nozzles. Good water quality is still important, so if there is any doubt we recommend testing it before installation. Checking the heads for clogging is part of the annual service.

Can you service a water mist system installed by another company?

Yes. We get many requests to service other misting systems, so we set up a maintenance service for existing mist systems. Our in-house engineers are experienced in mist suppression and can put a service contract in place for your current system.

CASE STUDY

Bristol Apartment Block

PROJECT SUMMARY

Sprinkler Retrofit for a Bristol Apartment Block

SmartMist was tasked with retrofitting a sprinkler system into a newly constructed apartment block in Bristol following late-stage requirements from building control. This intervention was necessary to provide a compliant means of escape and to ensure the building met the updated fire safety regulations, specifically BS 9991.

THE CHALLENGE

The building had an adequate mains water supply providing 35 LPM, but building control required a sprinkler system to ensure a compliant means of escape.

‍

This necessitated the retrofitting of a sprinkler system into the building's existing structure with minimal disruption to other ongoing works.

‍

In addition, the installation had to be completed rapidly, as building control's requirement was introduced late in the project, leaving limited time for adjustments.

THE SOLUTION

SmartMist installed a full sprinkler system that met BS 9251:2021 requirements. The system included sprinkler heads in all communal areas, such as hallways and stairwells, ensuring safe evacuation routes in case of fire.

‍

Although the mains water supply was adequate, a 1,000-litre water storage tank was added to the plant room in the basement to provide sufficient water pressure and flow during simultaneous sprinkler activation.

‍

This tank ensured the system could perform at full capacity in case of an emergency.

CLIENT RESPONSE

The client was extremely pleased with how SmartMist managed the project, especially given the tight timeline and the late-stage intervention required by building control.

‍

The rapid retrofit of the sprinkler system was completed with minimal disruption, and the system passed all necessary compliance tests.

‍

The client expressed confidence in the safety enhancements made to the building and appreciated the seamless integration of the system into the existing infrastructure.

CASE STUDY

Airbnb Holiday Apartments, Southwold

PROJECT SUMMARY

Enhancing Fire Safety in Airbnb Holiday Apartments, Southwold, UK

Our client, an operator of three holiday homes primarily rented through Airbnb, expressed a strong desire to integrate advanced fire safety measures into their properties. This initiative was particularly timely, as the UK Government had introduced new fire safety regulations for holiday lets in October 2023.

THE CHALLENGE

At SmartMist, our objective was to develop a fire suppression design that not only complied with the latest fire safety guidelines but also anticipated potential future amendments to these regulations. Our focus was to ensure the safety of visitors while offering a cost-effective solution for our client.

THE SOLUTION

We engineered a comprehensive fire safety design featuring a" means of escape" strategy. This involved the installation of a seven-mist-head system in each property, providing effective fire suppression along the escape routes leading to both the front and back doors. Remarkably, this retrofit installation was accomplished within a single day, minimising disruption.

CLIENT RESPONSE

The client expressed great satisfaction with the SmartMist system. She highlighted the peace of mind it brought her, stating, "I can sleep a bit more soundly knowing that I have the SmartMist system in place."

Want to learn more?

If you have any specific questions you would like to ask, please feel free to give us a call at any time that suits you. Our team is always ready to speak with you. Click the button below to speak to one of our team members today.

phone icon

Speak to our team today

0330 113 5900

Expert advice. Bespoke solutions. No obligation.

Get a quote

Call Us