Water mist and sprinkler systems for hospitals, mental health units and healthcare buildings. Designed around HTM 05-02 and your fire strategy, and installed without disrupting patient care.

✓ Water mist & sprinklers
✓ Design to commissioning
✓ UK-wide installation
Hospital Fire Suppression Systems

Water mist or sprinklers: independent advice, design and installation

As a commercial fire suppression specialist, we design and install both water mist and sprinkler systems, so we can recommend what actually suits your building, budget and fire strategy.

LPCB-certified water mist nozzles and in-house compliance expertise

Our commercial water mist systems use LPCB-certified nozzles. Our in-house compliance team prepares statements of equivalence and works directly with fire engineers, approved inspectors and fire authorities.

Full BIM coordination in Revit and AutoCAD

We coordinate fire suppression design with M&E and other services using BIM, cutting clashes on site and helping consultants and main contractors keep projects on programme.

UK water mist manufacturer with nationwide installation

We’re a SafeContractor-approved, British manufacturer of water mist fire suppression systems, supplying, installing and maintaining commercial systems across the UK through our accredited network.

OverviewRisk factorsRegulationsMist or sprinklerDesignStandardsProjectMaintenance & costFAQsEnquire
Commercial fire protection

Fire protection for healthcare buildings

Hospitals can't simply evacuate. Many patients can't move without help, so healthcare buildings rely on containing a fire and moving people horizontally to a safe area. Suppression that controls a fire early buys that time.

SmartMist offers full design, installation, commissioning and servicing of accredited water mist suppression for hospitals and healthcare buildings, carried out by our in-house fire technicians across England, Scotland and Wales. Only the heads nearest the fire activate, the system runs quietly, and semi-concealed heads suit mental health settings where tamper resistance matters.

  • Acute hospitals, private hospitals and clinics
  • Mental health and secure units
  • Plant rooms and generators for critical power
See all commercial fire suppression →
Fire protection for healthcare buildings
What shapes the design

What shapes hospital fire protection

Two sites with the same floor area can need very different systems. These are the factors we look at first.

Patients who can't evacuate

Healthcare buildings use progressive horizontal evacuation. Suppression helps keep a fire small while patients are moved.

Mental health settings

Heads and pipework need to be tamper-resistant and suitable for ligature-reduced environments.

Clinical areas and equipment

Water damage to theatres, imaging and clinical equipment is costly. Mist limits the water used.

24/7 operation

Hospitals never close. Work has to be phased around clinical activity and infection control.

Critical power

Generators and plant rooms keep the hospital running in an emergency, and need their own protection.

Building height

Approved Document B expects sprinklers in buildings with a storey over 30m, which includes many hospital blocks.

Requirements

Do hospitals need sprinklers?

Not in every case. HTM 05-02 asks designers to consider sprinklers throughout or in specific areas, and they're required in buildings with a storey over 30m.

NHS guidance

HTM 05-02

Firecode guidance for the design of healthcare premises in England. It expects designers to consider the benefits of sprinklers throughout a building or in specific areas.

Building Regulations

Approved Document B

Requires sprinklers throughout buildings with a top storey more than 30m above ground, and sprinklers can reduce compartment and evacuation constraints.

Fire safety law

Fire Safety Order 2005

The Regulatory Reform (Fire Safety) Order 2005 requires a fire risk assessment, which must reflect patients' dependency and evacuation needs.

Choosing a system

Water mist or fire sprinklers?

We install both, so we recommend whichever meets your design standard with the least water and plant space.

Water mist

Less water, smaller plant

High-pressure water mist uses far less water than traditional sprinklers, protecting clinical equipment and helping wards return to use sooner. Smaller tanks and pipework save plant space, and semi-concealed, tamper-resistant heads suit mental health units.

Explore commercial water mist →
Fire sprinklers

The established, widely specified route

Sprinklers to BS EN 12845 or LPC Rules are often specified for new hospital buildings and tall blocks. Where your fire strategy calls for sprinklers, we design and install them, and coordinate them with compartmentation and evacuation strategy.

Explore commercial sprinklers →
Mist and sprinklers aren't interchangeable in every building. We confirm the design standard with your insurer and fire engineer before design, then recommend the system that meets it.
Design & installation

Designed with the building, installed around your operations

Healthcare systems are designed with your estates team and fire engineer, around the building's fire strategy and HTM 05-02. We plan phasing around clinical activity, infection control and access restrictions.

Our in-house team installs, commissions and trains your staff, and provides servicing and 24/7 support afterwards.

Send your drawings

Phased installation

Work planned around wards and clinical activity.

Tamper-resistant heads

Semi-concealed heads for mental health settings.

Plant & generators

Protection for critical power and plant rooms.

Quiet operation

Low-noise systems suited to patient areas.

Standards & compliance

Standards for hospital fire suppression

Which standard applies depends on the system, the building and, often, your insurer.

Standard
Relevance
Status

HTM 05-02

NHS Firecode guidance on fire safety in the design of healthcare premises.

Current

Approved Document B

Building Regulations fire safety guidance, including the 30m sprinkler threshold.

Current

BS EN 12845

Automatic sprinkler design, installation and maintenance.

Current

BS EN 14972-1

Design, installation and maintenance framework for water mist systems.

Current

Fire Safety Order 2005

Requires a suitable fire risk assessment for the premises.

Current

This page explains typical requirements. It isn't a fire strategy or design specification.

Certification & accreditation

ISO 9001:2015
Quality management
SafeContractor
Health and safety accreditation

UK designed and built

Water mist and sprinkler systems

See all our accreditations →

Recent Clients

St Johns Wood Hospital, Generator Fire Suppression
Project example

St Johns Wood Hospital, Generator Fire Suppression

Hospital, Generator, London

In a significant refurbishment project, a prestigious private hospital in St Johns Wood upgraded its critical infrastructure, including the installation of a new diesel generator. SmartMist was chosen to equip the generator with a state-of-the-art water mist fire suppression system, ensuring the highest level of fire safety for the hospital’s crucial power source.

How we work

From drawings to handover

01

Review

Send drawings and the fire strategy. We'll confirm the likely system and design standard.

02

Design

Layouts, hydraulic calculations and documents for your insurer and Building Control.

03

Install

Planned around your build programme or operating hours.

04

Commission

Testing, handover pack and a maintenance plan from day one.

Aftercare

Servicing, including systems we didn't install

Commercial systems need an annual service, plus the routine owner checks the design standard sets. We test pumps and valves, check heads and nozzles for damage and obstruction, and provide the service records insurers expect. We also maintain systems installed by other contractors.

Service & maintenance plans →
Cost

What affects the price

  • Building size and areas protected: whole building or specific areas
  • Phasing: work around clinical activity adds time
  • Mental health requirements: tamper-resistant heads and fittings
  • Mist or sprinkler: changes tank, pump and pipe size
  • Infection control: enclosures and working restrictions
  • Plant and generators: separate protection for critical power

Most projects are quoted after a drawing review.

Read our cost guide →
Guides

Regulations and guidance

FAQs

Hospital fire suppression FAQs

Do hospitals need sprinklers?

Not in every case. HTM 05-02 asks designers to consider sprinklers throughout a building or in specific areas, and Approved Document B requires them in buildings with a storey more than 30m above ground. Your fire strategy will set out where they're needed.

Can you install a system without disrupting patient care?

Yes. We phase work around wards and clinical activity, follow infection control requirements and work with your estates team throughout.

Is water mist suitable for mental health units?

Yes. Semi-concealed, tamper-resistant heads and discreet pipework suit mental health and secure settings.

Can you protect hospital generators and plant rooms?

Yes. We installed a water mist system on a new diesel generator at a private hospital in St John's Wood, fitted into a refurbished plant room without disrupting the hospital.

Do you provide both installation and ongoing maintenance?

Yes. We offer a full service including design, installation, commissioning, scheduled maintenance, compliance checks, and emergency support.

Can you take over an existing system installed by another provider?

Yes. We can inspect, upgrade, and maintain existing mist or sprinkler systems to bring them in line with current regulations and performance expectations.

What standards do your systems comply with?

Our commercial water mist systems are designed to BS EN 14972-1, and our commercial sprinkler systems to BS EN 12845.

For residential projects, our sprinklers are designed to BS 9251. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. We also work to project and insurer requirements.

How do you determine which system is right for me?

We assess your fire strategy, occupancy type, building design, and water supply. Based on this, we may recommend high-pressure mist, low-pressure mist, wet or dry sprinkler systems, or a hybrid approach.

How often should my system be serviced?

We recommend annual servicing in line with BS 9251, BS EN 14972-1 or BS EN 12845, depending on the system type. In high-risk or heavily used environments, more frequent checks may be required.

Do you install both mist and sprinkler systems?

Yes. SmartMist offers both advanced water mist systems and traditional commercial sprinkler systems. We recommend the most suitable option based on your building’s fire strategy, layout, risk profile, and water supply.

Can fire sprinklers be retrofitted into an existing building?

Yes, fire sprinkler systems can be retrofitted into most commercial buildings. However, factors such as ceiling space, water supply, and pipe routing must be considered. Retrofitting is often recommended for older buildings, hotels, offices, and apartment blocks to enhance fire safety without major structural changes.

Get a quote

Have a project in mind?

Send what you have. These help us quote faster:

  1. Site plan and building drawings
  2. Areas or wards to protect
  3. Clinical activity and access restrictions
  4. Mental health or secure areas
  5. Fire strategy and HTM 05-02 requirements
  6. Water supply and plant space
  7. Generators or plant rooms to protect
  8. Programme and phasing constraints

Or call 0330 113 5900

Upload Floor Plan Drag and drop files here or click to choose
No file chosen
Should be Empty:
Related

Other commercial sectors