Residential Fire Suppression


Water mist and sprinkler systems for hotels, guesthouses and holiday lets. Discreet protection for guest rooms and shared spaces, designed to limit damage and keep rooms bookable.

Fire tested to BS EN 14972-17:2025, the new UK standard for home water mist
Our residential water mist system has passed full-scale fire tests to BS EN 14972-17 at the FPA, a UKAS-accredited test house, making us one of the first UK companies to do so. It’s the standard that replaced BS 8458, which gives Building Control and approved inspectors confidence in your fire strategy.
Open-plan fire safety without the fire doors
Keep your open-plan kitchen, loft conversion or living space. Discreet DOME water mist nozzles provide an approved alternative to protected escape routes and can reduce the need for fire doors, subject to Building Control.
80% less water than a domestic sprinkler system
Our DOME Gen 2 nozzle uses around 8 litres per minute, compared with 45 to 60 for a typical sprinkler head. That means less water damage, smaller pipework, and in most homes no water storage tank.
British-designed, made and installed, with Building Control support
We design, manufacture, install and maintain every home water mist system in-house. Our compliance team works directly with Building Control to help get your project signed off.
Guests sleep in unfamiliar buildings and may not know the way out. A fire in one room can close a floor, cancel bookings and damage interiors that took years to build up.
SmartMist designs and installs water mist systems for hotels, boutique guesthouses and Airbnb holiday lets. Water mist controls a fire quickly with far less water than sprinklers, and a wide range of heads means protection that sits quietly in your décor.

Two homes with the same floor area can need very different systems. These are the factors we look at first.
Guests are asleep and in an unfamiliar building. Early control of a fire buys time to get them out.
A three-bedroom holiday let and a 400-room hotel need very different systems, from a single pump unit to a whole-building design.
Water damage closes rooms. Water mist uses far less water, so rooms can be back in use sooner.
Hotels rarely close for an install. Work is planned floor by floor or between bookings.
Restaurants, kitchens and lounges have their own risks and may need separate protection.
Every paying guest property needs a written fire risk assessment, which often drives what's installed.
Usually it isn't a blanket legal requirement, but every hotel and holiday let must have a written fire risk assessment, and suppression is a common way to reduce the risks it finds.
Applies to hotels, B&Bs and holiday lets. Since October 2023, every paying guest property needs a written fire risk assessment.
Conversions and new hotels go through Building Control. Suppression can support the fire strategy, such as longer escape routes.
Scotland requires a short-term let licence. Wales requires sprinklers in some converted residential premises.
We install both, so we recommend whichever meets your design standard with the least water and disruption.
Water mist uses a fraction of the water of a sprinkler, protecting furnishings and the rooms below and cutting clean-up time. Smaller properties can often run from the mains, and a wide range of compliant heads blends into guest rooms.
Explore residential water mist →Sprinklers to BS 9251 or BS EN 12845 are the established route in larger hotels and where a fire strategy or insurer specifies them. We design and install both, and can combine them, for example sprinklers in back-of-house areas and mist in guest rooms.
Explore residential sprinklers →Every property is different, so we design around yours: the layout, the water supply, the look of the rooms and how you operate. Heads are chosen to suit your interiors.
Installation is planned around bookings, floor by floor in a hotel or between stays in a holiday let, and we provide servicing after handover.
Discreet heads chosen to suit your interiors.
Protection for shared escape routes.
Lounges, restaurants and back-of-house areas.
Systems that can extend with future refurbishments.
Which standard applies depends on the system, the building and, often, Building Control.
Requires a written fire risk assessment for all paying guest accommodation.
The European fire test standard for residential water mist. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.
The former UK residential water mist standard, withdrawn by BSI in July 2025 and replaced by BS EN 14972-17.
Water mist fire test protocol for offices, school classrooms and hotels.
The European standard for water mist design, installation, inspection and maintenance. Every SmartMist water mist installation is designed to it.
Code of practice for sprinkler systems in domestic and residential occupancies.
This page explains typical requirements. It isn't a fire strategy or design specification.
Tested to BS EN 14972-17:2025 at the FPA
Our SmartMist DOME™ residential water mist system met the performance criteria of the open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory. Every installation is designed to BS EN 14972-1.

Hotel, Edinburgh, Scotland
Client: Main Contractor (Longstanding SmartMist Partner)
Location: Edinburgh, Scotland
Project Duration: 8 Months On-Site
SmartMist Role: Design and Installation of Water Mist Fire Suppression System
SmartMist was entrusted by a leading main contractor to deliver a state-of-the-art water mist fire suppression system for a high-profile refurbishment project in Edinburgh.
This ambitious transformation converted a former office block into a luxurious 400-room hotel, requiring a fire safety solution that balanced exceptional performance with aesthetic discretion.
Over eight months, SmartMist designed and installed a tailored system, seamlessly coordinating with multiple trades to meet the project’s demanding requirements while adhering to UK fire safety standards.
Send drawings and the fire strategy. We'll confirm the likely system and design standard.
Layouts, hydraulic calculations and documents for Building Control and your warranty provider.
Planned around your build programme or residents.
Testing, handover pack and a maintenance plan from day one.
Residential systems need an annual service, plus the simple owner checks the design standard sets. We check pumps, valves and heads, and keep the records Building Control, landlords and insurers expect. We also maintain systems installed by other contractors.
Service & maintenance plans →Most projects are quoted after a drawing review.
Read our cost guide →Not usually by law, but since October 2023 every paying guest property in England and Wales needs a written fire risk assessment. Suppression is a common way to reduce the risks it finds, especially in older buildings, upper floors or properties with long escape routes.
Water mist uses far less water than sprinklers and only the heads near the fire activate. That means less damage to furnishings and the rooms below, and rooms back in use sooner.
Yes. We plan work floor by floor or around bookings, so most of the hotel stays open.
We use a range of compliant heads, including flush and concealed options, chosen to suit your interiors.
No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.
Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.
Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.
BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.
No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.
No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).
A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.
Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.
Send what you have. These help us quote faster:
Or call 0330 113 5900