Server Room & Data Centre Fire Suppression

Water mist suppression for server rooms, comms rooms and data centres. Protects equipment and uptime without the room sealing and refills gas systems need.

✓ Water mist & sprinklers
✓ Design to commissioning
✓ UK-wide installation
Server Room & Data Centre Fire Suppression

Water mist or sprinklers: independent advice, design and installation

As a commercial fire suppression specialist, we design and install both water mist and sprinkler systems, so we can recommend what actually suits your building, budget and fire strategy.

LPCB-certified water mist nozzles and in-house compliance expertise

Our commercial water mist systems use LPCB-certified nozzles. Our in-house compliance team prepares statements of equivalence and works directly with fire engineers, approved inspectors and fire authorities.

Full BIM coordination in Revit and AutoCAD

We coordinate fire suppression design with M&E and other services using BIM, cutting clashes on site and helping consultants and main contractors keep projects on programme.

UK water mist manufacturer with nationwide installation

We’re a SafeContractor-approved, British manufacturer of water mist fire suppression systems, supplying, installing and maintaining commercial systems across the UK through our accredited network.

OverviewRisk factorsRegulationsMist or sprinklerDesignStandardsMaintenance & costFAQsEnquire
Commercial fire protection

Fire protection that keeps your data online

An uncontrolled fire in a data centre or server room can be catastrophic, taking services offline and destroying equipment and data. Electrical faults, battery systems and cabling are common causes, and the cost of downtime often outweighs the damage itself.

SmartMist provides high-pressure water mist suppression for data centres and server rooms, designed, installed and project-managed in-house. Each project is researched individually to protect both the equipment and the building, and our systems can work alongside existing suppression already in place.

  • Data halls, server rooms and comms rooms
  • UPS and battery rooms
  • Works alongside existing gas or sprinkler systems
See all commercial fire suppression →
Fire protection that keeps your data online
What shapes the design

What shapes data centre fire protection

Two sites with the same floor area can need very different systems. These are the factors we look at first.

Electrical and battery fires

Power distribution, UPS and lithium-ion batteries are common ignition sources and can reignite after a fire is knocked down.

Downtime

For most operators the cost of an outage is greater than the cost of the damage, so a fire has to be controlled fast.

Water and equipment

Traditional sprinklers can damage equipment beyond the fire. Mist uses a fraction of the water and cools without drenching.

Room integrity

Gas systems rely on a sealed room to hold their concentration. Mist doesn't, which helps in rooms with cable penetrations and airflow.

Airflow and cooling

High airflow from cooling systems affects detection and suppression, and has to be considered in the design.

Insurer and client requirements

Insurers and colocation clients often specify approved systems, such as FM Approvals.

Requirements

Can you use water to protect a server room?

Yes. High-pressure water mist uses so little water it can protect live equipment, and water mist systems can be approved for data processing equipment rooms under FM 5560.

Approvals

FM 5560

FM Approvals' standard for water mist systems, with test protocols for data processing equipment rooms and halls. Many insurers ask for FM Approved systems.

Data centre design

EN 50600

The European data centre standard covers fire protection as part of the facility's design, alongside power and cooling.

Insurers

Insurer requirements

Insurers and colocation clients often specify approved suppression and documented maintenance as a condition of cover or contract.

Choosing a system

Water mist or fire sprinklers?

We install both, so we recommend whichever meets your design standard with the least water and plant space.

Water mist

Less water, smaller plant

High-pressure water mist cools the fire and the surrounding equipment with very little water, reducing the risk of reignition from batteries. Unlike gas systems, it doesn't need a sealed room or costly agent refills after discharge.

Explore commercial water mist →
Fire sprinklers

The established, widely specified route

Pre-action sprinklers are common in data centres, especially where an insurer specifies them. The pipes stay dry until detection confirms a fire, so a damaged pipe can't flood the room. We design and install pre-action systems where they're the right fit.

Explore commercial sprinklers →
Mist and sprinklers aren't interchangeable in every building. We confirm the design standard with your insurer and fire engineer before design, then recommend the system that meets it.
Design & installation

Designed with the building, installed around your operations

Data centre systems are designed around the room: its layout, airflow, cable routes and the equipment it holds. We coordinate with your M&E, cooling and detection teams, and plan installation so live services aren't interrupted.

Mist systems can be added alongside existing gas or sprinkler protection, for example to cover battery rooms or new halls.

Send your drawings

Data halls

Ceiling and underfloor protection for server rows.

UPS & batteries

Protection for battery rooms and power systems.

Detection

Early warning linked to mist activation.

Live installation

Work planned so services stay online.

Standards & compliance

Standards for data centre fire suppression

Which standard applies depends on the system, the building and, often, your insurer.

Standard
Relevance
Status

FM 5560

FM Approvals standard for water mist, including data processing rooms.

Current

BS EN 14972-1

Design, installation and maintenance framework for water mist systems.

Current

EN 50600

European standard for data centre facilities and infrastructures.

Current

BS EN 15004

Gaseous suppression design, for comparison or existing gas systems.

Current

BS EN 12845

Automatic sprinkler design, including pre-action systems.

Current

This page explains typical requirements. It isn't a fire strategy or design specification.

Certification & accreditation

ISO 9001:2015
Quality management
SafeContractor
Health and safety accreditation

UK designed and built

Water mist and sprinkler systems

See all our accreditations →

Recent Clients

How we work

From drawings to handover

01

Review

Send drawings and the fire strategy. We'll confirm the likely system and design standard.

02

Design

Layouts, hydraulic calculations and documents for your insurer and Building Control.

03

Install

Planned around your build programme or operating hours.

04

Commission

Testing, handover pack and a maintenance plan from day one.

Aftercare

Servicing, including systems we didn't install

Commercial systems need an annual service, plus the routine owner checks the design standard sets. We test pumps and valves, check heads and nozzles for damage and obstruction, and provide the service records insurers expect. We also maintain systems installed by other contractors.

Service & maintenance plans →
Cost

What affects the price

  • Room size and number of rooms: sets nozzle count
  • Mist, gas or pre-action: each has different equipment
  • Underfloor and ceiling voids: extra protection zones
  • Detection: early warning and interlocks
  • Live environment: out-of-hours and controlled work
  • Existing systems: integration with current suppression

Most projects are quoted after a drawing review.

Read our cost guide →
Guides

Regulations and guidance

FAQs

Server room and data centre fire suppression FAQs

Can you use water mist in a server room?

Yes. High-pressure water mist uses so little water that it can protect live equipment, and it's FM Approved for data processing equipment rooms and halls.

Is water mist better than a gas system for a data centre?

Each has its place. Gas systems need a sealed room and agent refills after discharge. Water mist doesn't need room sealing, cools the fire and nearby equipment, and helps prevent battery fires reigniting.

Can you add mist protection to a room that already has gas suppression?

Yes. Our systems can work alongside existing suppression, for example to cover battery rooms or new halls.

Can you install without taking services offline?

Yes. We plan work with your operations team in agreed change windows so live services stay up.

Do you provide both installation and ongoing maintenance?

Yes. We offer a full service including design, installation, commissioning, scheduled maintenance, compliance checks, and emergency support.

Can you take over an existing system installed by another provider?

Yes. We can inspect, upgrade, and maintain existing mist or sprinkler systems to bring them in line with current regulations and performance expectations.

What standards do your systems comply with?

Our commercial water mist systems are designed to BS EN 14972-1, and our commercial sprinkler systems to BS EN 12845.

For residential projects, our sprinklers are designed to BS 9251. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. We also work to project and insurer requirements.

How do you determine which system is right for me?

We assess your fire strategy, occupancy type, building design, and water supply. Based on this, we may recommend high-pressure mist, low-pressure mist, wet or dry sprinkler systems, or a hybrid approach.

How often should my system be serviced?

We recommend annual servicing in line with BS 9251, BS EN 14972-1 or BS EN 12845, depending on the system type. In high-risk or heavily used environments, more frequent checks may be required.

Do you install both mist and sprinkler systems?

Yes. SmartMist offers both advanced water mist systems and traditional commercial sprinkler systems. We recommend the most suitable option based on your building’s fire strategy, layout, risk profile, and water supply.

Get a quote

Have a project in mind?

Send what you have. These help us quote faster:

  1. Room plans and rack layout
  2. Room sizes and ceiling and floor voids
  3. UPS and battery locations
  4. Existing suppression or detection
  5. Insurer or client requirements
  6. Cooling and airflow arrangement
  7. Water supply and plant space
  8. Change windows for live work

Or call 0330 113 5900