Residential Fire Suppression


Sprinkler and water mist systems for new homes and apartment developments. Designed with your team, installed to your build programme, and signed off for Building Control and warranty providers.

Fire tested to BS EN 14972-17:2025, the new UK standard for home water mist
Our residential water mist system has passed full-scale fire tests to BS EN 14972-17 at the FPA, a UKAS-accredited test house, making us one of the first UK companies to do so. It’s the standard that replaced BS 8458, which gives Building Control and approved inspectors confidence in your fire strategy.
Open-plan fire safety without the fire doors
Keep your open-plan kitchen, loft conversion or living space. Discreet DOME water mist nozzles provide an approved alternative to protected escape routes and can reduce the need for fire doors, subject to Building Control.
80% less water than a domestic sprinkler system
Our DOME Gen 2 nozzle uses around 8 litres per minute, compared with 45 to 60 for a typical sprinkler head. That means less water damage, smaller pipework, and in most homes no water storage tank.
British-designed, made and installed, with Building Control support
We design, manufacture, install and maintain every home water mist system in-house. Our compliance team works directly with Building Control to help get your project signed off.
On a new development, fire suppression is easiest and cheapest when it's designed in from the start. Late changes from Building Control can mean retrofitting into finished homes and delaying handover.
SmartMist designs and installs water mist and sprinkler systems for developers and contractors across the UK. We work from the design stage, agree the standard with your fire engineer and Building Control, and fit the system to your build programme.

Two homes with the same floor area can need very different systems. These are the factors we look at first.
Wales requires sprinklers in all new homes. Scotland requires them in new flats and social housing. England in flats 11m and over.
Houses, low-rise flats and tall blocks each have different triggers and design standards.
Suppression can allow open-plan layouts, longer escape routes or fewer fire doors.
Mains capacity decides whether each home needs a tank, or a block needs a pump set.
First and second fix need to fit around other trades and handover dates.
Building Control and warranty providers need certificates for every plot.
In Wales, all new homes do. In Scotland, new flats and social housing do. In England, new blocks of flats 11m and over do, and other homes may where the design relies on it.
Sprinklers have been required in all new and converted houses and flats in Wales since January 2016.
Since March 2021, new flats, social housing and shared multi-occupancy buildings need automatic fire suppression.
Sprinklers throughout new blocks of flats 11m and over, and a second staircase in new blocks 18m and over.
We install both, so we recommend whichever meets your design standard with the least water and disruption.
Water mist uses a fraction of the water of a sprinkler, so many homes run from the mains without a tank. Small-bore pipework is quick to install at first fix, and discreet heads suit finished interiors.
Explore residential water mist →Residential sprinklers to BS 9251 are the established route and the one many fire strategies specify, particularly in apartment blocks. We design and install both, including tank and pump sets for larger buildings.
Explore residential sprinklers →We join at design stage, agree the standard with your fire engineer and Building Control, and coordinate pipe routes with your M&E design.
Installation follows your programme, plot by plot or block by block, with certificates for Building Control and your warranty provider at handover.
Standard and layouts agreed before construction.
First and second fix to your build programme.
Mains-fed homes or tank and pump sets for blocks.
Certificates for Building Control and warranty.
Which standard applies depends on the system, the building and, often, Building Control.
Sprinklers in new blocks of flats 11m and over; second staircase at 18m and over.
Code of practice for sprinkler systems in domestic and residential occupancies.
Fire safety in the design, management and use of residential buildings.
The European fire test standard for residential water mist. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.
The former UK residential water mist standard, withdrawn by BSI in July 2025 and replaced by BS EN 14972-17.
The European standard for water mist design, installation, inspection and maintenance. Every SmartMist water mist installation is designed to it.
This page explains typical requirements. It isn't a fire strategy or design specification.
Tested to BS EN 14972-17:2025 at the FPA
Our SmartMist DOME™ residential water mist system met the performance criteria of the open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory. Every installation is designed to BS EN 14972-1.

Apartment Block, Swansea, Wales
SmartMist was entrusted with the fire safety system for a modern eight-apartment block in Swansea. Adhering to the stringent full-coverage fire regulations in Wales, our task was to implement a state-of-the-art mist system in each apartment, ensuring the highest safety standards.
This development, aimed at the sales market, required a fire safety system that would not only provide exceptional protection but also appeal to potential buyers. Each of the six apartments was to be equipped with six mist heads and an individual pump, offering a complete fire suppression solution.
Send drawings and the fire strategy. We'll confirm the likely system and design standard.
Layouts, hydraulic calculations and documents for Building Control and your warranty provider.
Planned around your build programme or residents.
Testing, handover pack and a maintenance plan from day one.
Residential systems need an annual service, plus the simple owner checks the design standard sets. We check pumps, valves and heads, and keep the records Building Control, landlords and insurers expect. We also maintain systems installed by other contractors.
Service & maintenance plans →Most projects are quoted after a drawing review.
Read our cost guide →In Wales, yes: all new homes have needed sprinklers since 2016. In Scotland, new flats and social housing need them. In England, most new houses don't, unless the design relies on them, for example an open-plan layout.
At design stage. Agreeing the standard with Building Control and your fire engineer early avoids late changes and retrofitting into finished homes.
Yes. We fit first fix with other services and second fix after decoration, plot by plot or block by block, to match your handover dates.
Commissioning certificates for each plot for Building Control and your warranty provider, plus a maintenance plan for the homeowner or managing agent.
No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.
Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.
Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.
BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.
No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.
No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).
A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.
Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.
Send what you have. These help us quote faster:
Or call 0330 113 5900