Water mist and sprinkler systems for individual flats and apartment buildings. Low water use, discreet heads and installs planned around residents, from luxury apartments to whole blocks.

✓ Water mist & sprinklers
✓ Design to commissioning
✓ UK-wide installation
Fire Suppression for Flats & Apartments

Fire tested to BS EN 14972-17:2025, the new UK standard for home water mist

Our residential water mist system has passed full-scale fire tests to BS EN 14972-17 at the FPA, a UKAS-accredited test house, making us one of the first UK companies to do so. It’s the standard that replaced BS 8458, which gives Building Control and approved inspectors confidence in your fire strategy.

Open-plan fire safety without the fire doors

Keep your open-plan kitchen, loft conversion or living space. Discreet DOME water mist nozzles provide an approved alternative to protected escape routes and can reduce the need for fire doors, subject to Building Control.

80% less water than a domestic sprinkler system

Our DOME Gen 2 nozzle uses around 8 litres per minute, compared with 45 to 60 for a typical sprinkler head. That means less water damage, smaller pipework, and in most homes no water storage tank.

British-designed, made and installed, with Building Control support

We design, manufacture, install and maintain every home water mist system in-house. Our compliance team works directly with Building Control to help get your project signed off.

OverviewRisk factorsRegulationsMist or sprinklerDesignStandardsProjectMaintenance & costFAQsEnquire
Residential fire protection

Fire protection for flats and apartments

Most fires in flats start in the kitchen, and in a building with shared walls and escape routes a fire in one home affects everyone. Suppression controls the fire where it starts and limits smoke in the flat and the common parts.

SmartMist designs and installs water mist and sprinkler systems for individual flats and whole apartment buildings. Our water mist system uses very little water, protecting your home and the flats below, and can be fitted in occupied homes with minimal disruption.

  • Individual flats and whole buildings
  • Luxury apartments and conversions
  • New builds and occupied retrofits
See all residential fire suppression →
Fire protection for flats and apartments
What shapes the design

What shapes fire protection in a flat

Two homes with the same floor area can need very different systems. These are the factors we look at first.

Kitchens

Most flat fires start in the kitchen. Coverage there matters most.

Open-plan layouts

Open-plan flats can have longer escape routes through the living space. Suppression can make them acceptable.

Flats below

Water damage spreads downward. Water mist uses far less water than sprinklers.

Building height

New blocks of flats 11m and over in England need sprinklers throughout.

Occupied homes

Retrofits happen around residents, so small pipework and quick installs help.

Leasehold and management

Whole-building systems need agreement from the freeholder or managing agent.

Requirements

Do flats need sprinklers?

New blocks of flats in England need sprinklers if a storey is 11m or more above ground. In Scotland and Wales, all new flats need them. Elsewhere, they're often used to allow open-plan layouts.

England

Approved Document B

Sprinklers throughout new blocks of flats 11m and over. Below that, suppression can support open-plan flats.

Scotland & Wales

Devolved rules

Scotland requires fire suppression in all new flats. Wales has required sprinklers in all new and converted flats since 2016.

Existing blocks

Fire Safety (England) Regulations 2022

Responsible persons in blocks of flats have extra duties, and fire risk assessments may recommend suppression.

Choosing a system

Water mist or fire sprinklers?

We install both, so we recommend whichever meets your design standard with the least water and disruption.

Water mist

Less water, often no tank

Water mist uses a fraction of the water of a sprinkler, limiting damage to your flat and the ones below. Small-bore pipework and a compact pump unit fit in occupied homes, and flush heads blend into the décor.

Explore residential water mist →
Fire sprinklers

The established, widely specified route

Residential sprinklers to BS 9251 are the established route in new blocks and the one many fire strategies specify. We design and install them, and can retrofit them where Building Control requires it late in a project.

Explore residential sprinklers →
Mist and sprinklers aren't interchangeable in every building. We confirm the design standard with Building Control and your fire engineer before design, then recommend the system that meets it.
Design & installation

Designed with the building, installed around residents

For individual flats we survey the layout, agree what Building Control or your fire strategy needs, and fit a self-contained system with its own pump. For whole buildings we design with your fire engineer and managing agent.

We integrate the system with the fire alarm and leave each home tidy at the end of the day.

Send your drawings

Kitchens & living

Coverage where fires usually start.

Open-plan layouts

Protection that supports open-plan escape routes.

Pump units

Compact pumps for individual flats.

Alarm integration

Links to existing detection and alarms.

Standards & compliance

Standards for flat and apartment fire suppression

Which standard applies depends on the system, the building and, often, Building Control.

Standard
Relevance
Status

Approved Document B

Sprinklers throughout new blocks of flats 11m and over.

Current

BS 9251:2021

Code of practice for sprinkler systems in domestic and residential occupancies.

Current

BS 9991:2024

Fire safety in the design, management and use of residential buildings.

Current

BS EN 14972-17:2025

The European fire test standard for residential water mist. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.

Tested

BS 8458:2015

The former UK residential water mist standard, withdrawn by BSI in July 2025 and replaced by BS EN 14972-17.

Withdrawn

BS EN 14972-1

The European standard for water mist design, installation, inspection and maintenance. Every SmartMist water mist installation is designed to it.

Designed to

This page explains typical requirements. It isn't a fire strategy or design specification.

Certification & accreditation

ISO 9001:2015
Quality management
SafeContractor
Health and safety accreditation

Tested to BS EN 14972-17:2025 at the FPA

Our SmartMist DOME™ residential water mist system met the performance criteria of the open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory. Every installation is designed to BS EN 14972-1.

See all our accreditations →

Recent Clients

Residential Apartment, Water Mist System, Manchester
Project example

Residential Apartment, Water Mist System, Manchester

Apartment, Manchester

In 2023, a key project in downtown Manchester involved upgrading fire safety in a large residential complex. SmartMist was chosen for its expertise in fire protection, specifically for the installation of advanced mist systems in all apartment units.

How we work

From drawings to handover

01

Review

Send drawings and the fire strategy. We'll confirm the likely system and design standard.

02

Design

Layouts, hydraulic calculations and documents for Building Control and your warranty provider.

03

Install

Planned around your build programme or residents.

04

Commission

Testing, handover pack and a maintenance plan from day one.

Aftercare

Servicing, including systems we didn't install

Residential systems need an annual service, plus the simple owner checks the design standard sets. We check pumps, valves and heads, and keep the records Building Control, landlords and insurers expect. We also maintain systems installed by other contractors.

Service & maintenance plans →
Cost

What affects the price

  • Size and number of flats: sets head count
  • Mist or sprinkler: changes pipe size and whether a tank is needed
  • Single flat or whole building: pump unit per flat or a shared system
  • Occupied or vacant: occupied homes need careful access
  • Water supply: mains pressure and flow
  • Alarm integration: links to existing detection

Most projects are quoted after a drawing review.

Read our cost guide →
Guides

Regulations and guidance

FAQs

Flat & apartment fire suppression FAQs

Do flats need sprinklers?

New blocks of flats in England need sprinklers if a storey is 11m or more above ground. In Scotland and Wales, all new flats need automatic fire suppression. In other flats, suppression is often used to allow open-plan layouts.

Can I fit water mist in my own flat?

Yes. A self-contained system with its own compact pump can protect an individual flat. If you're a leaseholder, check with your freeholder or managing agent first.

Will a system flood the flat below?

Water mist uses far less water than sprinklers and only the heads near the fire activate, which limits damage to your flat and the ones below.

Can a flat system be installed while I live there?

Yes. Small-bore pipework and compact pumps keep disruption down, and we leave the flat tidy at the end of each day.

Is BS 8458 still current for water mist systems?

No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.

Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.

Are SmartMist residential water mist systems independently tested?

Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.

BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.

Will all the nozzles activate in my property in the event of a fire?

No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.

Does smoke caused by burning food trigger the water mist nozzle?

No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).

A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.

Are misting fire suppression systems safe for electronics and furniture?

Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.

Get a quote

Have a project in mind?

Send what you have. These help us quote faster:

  1. Floor plan of the flat or building
  2. Floor level and building height
  3. New build, conversion or existing
  4. Building Control or fire strategy requirements
  5. Freeholder or managing agent details
  6. Mains water details
  7. Occupied or vacant
  8. Preferred dates

Or call 0330 113 5900

Upload Floor Plan Drag and drop files here or click to choose
No file chosen
Should be Empty:
Related

Other residential sectors

No items found.
Get a quote

Call Us