Residential Fire Suppression


Water mist, local application and sprinkler systems for factories and industrial sites. Designed around your processes and machinery, and installed around shift patterns and planned downtime.

Water mist or sprinklers: independent advice, design and installation
As a commercial fire suppression specialist, we design and install both water mist and sprinkler systems, so we can recommend what actually suits your building, budget and fire strategy.
LPCB-certified water mist nozzles and in-house compliance expertise
Our commercial water mist systems use LPCB-certified nozzles. Our in-house compliance team prepares statements of equivalence and works directly with fire engineers, approved inspectors and fire authorities.
Full BIM coordination in Revit and AutoCAD
We coordinate fire suppression design with M&E and other services using BIM, cutting clashes on site and helping consultants and main contractors keep projects on programme.
UK water mist manufacturer with nationwide installation
We’re a SafeContractor-approved, British manufacturer of water mist fire suppression systems, supplying, installing and maintaining commercial systems across the UK through our accredited network.
Factories face higher fire risk than standard commercial sites: heat-generating machinery, heavy electrical loads, flammable materials and continuous production. A fire doesn't just damage plant; it stops output and can put contracts at risk.
SmartMist designs fire suppression around how your facility operates day to day. We look at where fires are most likely to start and design a system that fits those processes, from local protection on individual machines to full-building coverage, so fires are contained quickly and production interruptions are limited.

Two sites with the same floor area can need very different systems. These are the factors we look at first.
Machinery that runs for long hours can overheat. Local application systems protect individual machines without flooding the whole floor.
Oils, solvents, dusts and packaging raise the hazard. Where explosive atmospheres are possible, DSEAR applies.
Switchgear, motors and control panels are common ignition sources and need protection that won't make things worse.
Downtime is expensive. Systems should contain a fire fast and be installed around shifts and shutdowns.
Single-storey industrial buildings often have no Building Regulations sprinkler requirement, so protection is led by risk and insurers.
Insurers may require sprinklers or specific machinery protection, and their surveyors will review the design.
Not usually under Building Regulations for single-storey industrial buildings, but your fire risk assessment, DSEAR and your insurer often call for suppression.
The Regulatory Reform (Fire Safety) Order 2005 requires a fire risk assessment covering your processes, materials and machinery.
The Dangerous Substances and Explosive Atmospheres Regulations require you to control fire and explosion risks from flammable substances and dusts.
Insurers often require sprinklers or local machinery protection for higher-risk processes, and set the standard it must meet.
We install both, so we recommend whichever meets your design standard with the least water and plant space.
High-pressure water mist cools machinery and the surrounding area quickly with very little water, so equipment can be cleaned and restarted sooner. Local application systems protect individual machines and enclosures, tested to protocols such as BS EN 14972-8 and -9 for machinery spaces.
Explore commercial water mist →Sprinklers to BS EN 12845 or LPC Rules suit full-building protection of production and storage areas, and are often what insurers specify. We design and install them, and combine them with local machinery protection where needed.
Explore commercial sprinklers →We survey each site and speak to the people who run it, to understand where the risks are. Then we design around your processes, from self-contained systems on individual machines to full-building protection.
Installation is staged around shift patterns and planned downtime, so production keeps running.
Local application on high-risk machines and enclosures.
Heat and smoke detection, with double-knock to avoid false activation.
Cylinder-based systems where there's no water supply.
Work around shifts and planned shutdowns.
Which standard applies depends on the system, the building and, often, your insurer.
Automatic sprinkler design for production and storage areas.
Water mist test protocols for machinery in enclosures.
Design, installation and maintenance framework for water mist systems.
Regulations on fire and explosion risks from dangerous substances.
Requires a suitable fire risk assessment for the site.
This page explains typical requirements. It isn't a fire strategy or design specification.
UK designed and built
Water mist and sprinkler systems
.avif)
Plant Machinery, UK Nationwide
National services are often taken for granted, without thinking about the considerable investment into businesses and infrastructure that goes on behind the scenes.
Everyday processes are often assumed to just work; however, they are often driven by large, expensive pieces if machinery that require a lot of configuration, maintenance and monitoring. Not to mention the initial expense of the machinery, and the costs associated if it becomes damaged.
Send drawings and the fire strategy. We'll confirm the likely system and design standard.
Layouts, hydraulic calculations and documents for your insurer and Building Control.
Planned around your build programme or operating hours.
Testing, handover pack and a maintenance plan from day one.
Commercial systems need an annual service, plus the routine owner checks the design standard sets. We test pumps and valves, check heads and nozzles for damage and obstruction, and provide the service records insurers expect. We also maintain systems installed by other contractors.
Service & maintenance plans →Most projects are quoted after a drawing review.
Read our cost guide →Not usually under Building Regulations for single-storey industrial buildings. But your fire risk assessment, DSEAR where flammable substances are present, and your insurer often call for suppression, especially around high-risk machinery.
Yes. Local application systems protect specific machines or enclosures. We've installed self-contained systems on materials processing machinery that runs up to 20 hours a day.
Self-contained systems use stored water and nitrogen cylinders, so they don't need a mains connection or tank.
We stage installation around shift patterns and planned downtime to keep production running.
Yes. We offer a full service including design, installation, commissioning, scheduled maintenance, compliance checks, and emergency support.
Yes. We can inspect, upgrade, and maintain existing mist or sprinkler systems to bring them in line with current regulations and performance expectations.
Our commercial water mist systems are designed to BS EN 14972-1, and our commercial sprinkler systems to BS EN 12845.
For residential projects, our sprinklers are designed to BS 9251. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. We also work to project and insurer requirements.
We assess your fire strategy, occupancy type, building design, and water supply. Based on this, we may recommend high-pressure mist, low-pressure mist, wet or dry sprinkler systems, or a hybrid approach.
We recommend annual servicing in line with BS 9251, BS EN 14972-1 or BS EN 12845, depending on the system type. In high-risk or heavily used environments, more frequent checks may be required.
Yes. SmartMist offers both advanced water mist systems and traditional commercial sprinkler systems. We recommend the most suitable option based on your building’s fire strategy, layout, risk profile, and water supply.
Yes, fire sprinkler systems can be retrofitted into most commercial buildings. However, factors such as ceiling space, water supply, and pipe routing must be considered. Retrofitting is often recommended for older buildings, hotels, offices, and apartment blocks to enhance fire safety without major structural changes.
Send what you have. These help us quote faster:
Or call 0330 113 5900