Home

›

Commercial

›

Warehouses

Commercial fire suppression

Warehouse Fire Suppression Systems

Sprinkler and water mist systems for warehouses, distribution centres and storage facilities. Designed around your racking, ceiling height and stored goods, and installed around round-the-clock operations.

✓ Water mist & sprinklers
✓ Design to commissioning
✓ UK-wide installation
Warehouse Fire Suppression Systems

Water mist or sprinklers: independent advice, design and installation

As a commercial fire suppression specialist, we design and install both water mist and sprinkler systems, so we can recommend what actually suits your building, budget and fire strategy.

LPCB-certified water mist nozzles and in-house compliance expertise

Our commercial water mist systems use LPCB-certified nozzles. Our in-house compliance team prepares statements of equivalence and works directly with fire engineers, approved inspectors and fire authorities.

Full BIM coordination in Revit and AutoCAD

We coordinate fire suppression design with M&E and other services using BIM, cutting clashes on site and helping consultants and main contractors keep projects on programme.

UK water mist manufacturer with nationwide installation

We’re a SafeContractor-approved, British manufacturer of water mist fire suppression systems, supplying, installing and maintaining commercial systems across the UK through our accredited network.

OverviewRisk factorsRegulationsMist or sprinklerDesignStandardsMaintenance & costFAQsEnquire
Commercial fire protection

Fire protection for large-scale storage

Warehouses face particular fire risks: large open spaces, high racking, combustible goods and continuous operations. A fire can reach the roof and spread across racking in minutes, and the loss of stock and the building can stop a business trading.

SmartMist designs and installs warehouse fire suppression to current UK standards, tailored to each site's layout, use and risk level. We assess ceiling height, storage type, airflow and how the building is used, so protection focuses where it's needed most.

  • Distribution centres, storage and logistics sites
  • Racked, block-stacked and mezzanine storage
  • Single sites to multi-location operations
See all commercial fire suppression →
Fire protection for large-scale storage
What shapes the design

What shapes warehouse fire protection

Two sites with the same floor area can need very different systems. These are the factors we look at first.

Storage height and racking

Higher racking needs more water and often in-rack sprinklers. Storage height is one of the biggest factors in system design.

What you store

Goods and packaging are classified into categories that set the design. Plastics, aerosols and lithium batteries raise the hazard.

Compartment size

Under Approved Document B, unsprinklered single-storey storage compartments are limited in size. Sprinklers remove that limit.

Insurer requirements

Insurers often set the standard for warehouses, commonly LPC Rules, and may require sprinklers as a condition of cover.

Water supply

Large warehouse systems need significant water storage and pumps. Tank and pump house space has to be planned early.

Changing use

New tenants, goods or racking can change the hazard. The system needs to be checked when the use changes.

Requirements

Do warehouses need sprinklers?

Large ones often do. Approved Document B limits unsprinklered single-storey storage compartments to 20,000 m², and insurers frequently require sprinklers regardless of size.

Building Regulations

Approved Document B

Unsprinklered single-storey storage compartments are limited to 20,000 m² where the building is under 18m. With sprinklers, there is no compartment size limit.

Insurers

LPC Rules

Many warehouse insurers specify LPC Rules for Automatic Sprinkler Installations, which build on BS EN 12845 with extra requirements.

Fire safety law

Fire Safety Order 2005

The Regulatory Reform (Fire Safety) Order 2005 requires a fire risk assessment, which must reflect what you store and how.

Choosing a system

Water mist or fire sprinklers?

We install both, so we recommend whichever meets your design standard with the least water and plant space.

Water mist

Less water, smaller plant

Water mist suits parts of a warehouse such as offices, plant rooms, battery charging areas and lower-height storage, where its low water use limits damage. High-piled racked storage is normally protected with sprinklers, and we'll tell you honestly which suits each area.

Explore commercial water mist →
Fire sprinklers

The established, widely specified route

Sprinklers to BS EN 12845 or LPC Rules are the standard approach for warehouses, including in-rack sprinklers for high racking. We design systems around your storage categories and heights, and can extend or modify existing systems when racking or tenants change.

Explore commercial sprinklers →
Mist and sprinklers aren't interchangeable in every building. We confirm the design standard with your insurer and fire engineer before design, then recommend the system that meets it.
Design & installation

Designed with the building, installed around your operations

Warehouse systems start with your storage: what's stored, how high and in what kind of racking. We design to the hazard, size the water supply and pumps, and coordinate with racking suppliers and your insurer.

Installation is planned around round-the-clock operations, with phased work or off-peak hours to keep goods moving.

Send your drawings

Storage assessment

Goods category, storage height and racking type.

In-rack protection

Sprinklers within racking where heights require it.

Water supply

Tanks and pump sets sized to the design.

Ancillary areas

Mist for offices, plant rooms and charging areas.

Standards & compliance

Standards for warehouse fire suppression

Which standard applies depends on the system, the building and, often, your insurer.

Standard
Relevance
Status

BS EN 12845

Automatic sprinkler design, including storage categories and in-rack protection.

Current

LPC Rules

Insurer sprinkler rules, widely specified for warehouses.

Current

Approved Document B

Building Regulations guidance, including compartment sizes for storage buildings.

Current

BS EN 14972-1

Design framework for water mist systems in ancillary areas.

Current

BS 9999

Fire safety in the design, management and use of buildings.

Current

This page explains typical requirements. It isn't a fire strategy or design specification.

Certification & accreditation

ISO 9001:2015
Quality management
SafeContractor
Health and safety accreditation

UK designed and built

Water mist and sprinkler systems

See all our accreditations →

Recent Clients

How we work

From drawings to handover

01

Review

Send drawings and the fire strategy. We'll confirm the likely system and design standard.

02

Design

Layouts, hydraulic calculations and documents for your insurer and Building Control.

03

Install

Planned around your build programme or operating hours.

04

Commission

Testing, handover pack and a maintenance plan from day one.

Aftercare

Servicing, including systems we didn't install

Commercial systems need an annual service, plus the routine owner checks the design standard sets. We test pumps and valves, check heads and nozzles for damage and obstruction, and provide the service records insurers expect. We also maintain systems installed by other contractors.

Service & maintenance plans →
Cost

What affects the price

  • Floor area and roof height: sets the size of the system
  • Storage height and racking: in-rack sprinklers add cost
  • Goods stored: higher hazard categories need more water
  • Water supply: tanks, pumps and a pump house
  • Existing system: extending or upgrading versus new
  • Operations: phased or off-peak installation

Most projects are quoted after a drawing review.

Read our cost guide →
Guides

Regulations and guidance

FAQs

Warehouse fire suppression FAQs

Do warehouses need sprinklers?

Large ones often do. Approved Document B limits unsprinklered single-storey storage compartments to 20,000 m² in buildings under 18m, and insurers frequently require sprinklers whatever the size, commonly to LPC Rules.

Do I need in-rack sprinklers?

It depends on your storage height, the goods stored and the racking. Above certain heights, roof-level sprinklers alone can't reach a fire in the racking, so sprinklers are fitted within the racks. We'll confirm after a survey.

Can water mist protect a warehouse?

Mist suits parts of a warehouse such as offices, plant rooms and battery charging areas. High-piled racked storage is normally protected with sprinklers to BS EN 12845 or LPC Rules.

Can you install while the warehouse is operating?

Yes. We plan installation around your operations, with phased work or off-peak hours to keep goods moving.

Do you provide both installation and ongoing maintenance?

Yes. We offer a full service including design, installation, commissioning, scheduled maintenance, compliance checks, and emergency support.

Can you take over an existing system installed by another provider?

Yes. We can inspect, upgrade, and maintain existing mist or sprinkler systems to bring them in line with current regulations and performance expectations.

What standards do your systems comply with?

Our commercial water mist systems are designed to BS EN 14972-1, and our commercial sprinkler systems to BS EN 12845.

For residential projects, our sprinklers are designed to BS 9251. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. We also work to project and insurer requirements.

How do you determine which system is right for me?

We assess your fire strategy, occupancy type, building design, and water supply. Based on this, we may recommend high-pressure mist, low-pressure mist, wet or dry sprinkler systems, or a hybrid approach.

How often should my system be serviced?

We recommend annual servicing in line with BS 9251, BS EN 14972-1 or BS EN 12845, depending on the system type. In high-risk or heavily used environments, more frequent checks may be required.

Do you install both mist and sprinkler systems?

Yes. SmartMist offers both advanced water mist systems and traditional commercial sprinkler systems. We recommend the most suitable option based on your building’s fire strategy, layout, risk profile, and water supply.

Can fire sprinklers be retrofitted into an existing building?

Yes, fire sprinkler systems can be retrofitted into most commercial buildings. However, factors such as ceiling space, water supply, and pipe routing must be considered. Retrofitting is often recommended for older buildings, hotels, offices, and apartment blocks to enhance fire safety without major structural changes.

Get a quote

Have a project in mind?

Send what you have. These help us quote faster:

  1. Site plan and building height
  2. Racking layout and storage heights
  3. Goods stored and packaging
  4. Insurer or LPC requirements
  5. Existing sprinklers, if any
  6. Water supply and space for tanks
  7. Planned changes to racking or tenants
  8. Operating hours

Or call 0330 113 5900

Upload Floor Plan Drag and drop files here or click to choose
No file chosen
Should be Empty:
Related

Other commercial sectors