Residential Fire Suppression


Sprinkler and water mist systems for warehouses, distribution centres and storage facilities. Designed around your racking, ceiling height and stored goods, and installed around round-the-clock operations.

Water mist or sprinklers: independent advice, design and installation
As a commercial fire suppression specialist, we design and install both water mist and sprinkler systems, so we can recommend what actually suits your building, budget and fire strategy.
LPCB-certified water mist nozzles and in-house compliance expertise
Our commercial water mist systems use LPCB-certified nozzles. Our in-house compliance team prepares statements of equivalence and works directly with fire engineers, approved inspectors and fire authorities.
Full BIM coordination in Revit and AutoCAD
We coordinate fire suppression design with M&E and other services using BIM, cutting clashes on site and helping consultants and main contractors keep projects on programme.
UK water mist manufacturer with nationwide installation
We’re a SafeContractor-approved, British manufacturer of water mist fire suppression systems, supplying, installing and maintaining commercial systems across the UK through our accredited network.
Warehouses face particular fire risks: large open spaces, high racking, combustible goods and continuous operations. A fire can reach the roof and spread across racking in minutes, and the loss of stock and the building can stop a business trading.
SmartMist designs and installs warehouse fire suppression to current UK standards, tailored to each site's layout, use and risk level. We assess ceiling height, storage type, airflow and how the building is used, so protection focuses where it's needed most.

Two sites with the same floor area can need very different systems. These are the factors we look at first.
Higher racking needs more water and often in-rack sprinklers. Storage height is one of the biggest factors in system design.
Goods and packaging are classified into categories that set the design. Plastics, aerosols and lithium batteries raise the hazard.
Under Approved Document B, unsprinklered single-storey storage compartments are limited in size. Sprinklers remove that limit.
Insurers often set the standard for warehouses, commonly LPC Rules, and may require sprinklers as a condition of cover.
Large warehouse systems need significant water storage and pumps. Tank and pump house space has to be planned early.
New tenants, goods or racking can change the hazard. The system needs to be checked when the use changes.
Large ones often do. Approved Document B limits unsprinklered single-storey storage compartments to 20,000 m², and insurers frequently require sprinklers regardless of size.
Unsprinklered single-storey storage compartments are limited to 20,000 m² where the building is under 18m. With sprinklers, there is no compartment size limit.
Many warehouse insurers specify LPC Rules for Automatic Sprinkler Installations, which build on BS EN 12845 with extra requirements.
The Regulatory Reform (Fire Safety) Order 2005 requires a fire risk assessment, which must reflect what you store and how.
We install both, so we recommend whichever meets your design standard with the least water and plant space.
Water mist suits parts of a warehouse such as offices, plant rooms, battery charging areas and lower-height storage, where its low water use limits damage. High-piled racked storage is normally protected with sprinklers, and we'll tell you honestly which suits each area.
Explore commercial water mist →Sprinklers to BS EN 12845 or LPC Rules are the standard approach for warehouses, including in-rack sprinklers for high racking. We design systems around your storage categories and heights, and can extend or modify existing systems when racking or tenants change.
Explore commercial sprinklers →Warehouse systems start with your storage: what's stored, how high and in what kind of racking. We design to the hazard, size the water supply and pumps, and coordinate with racking suppliers and your insurer.
Installation is planned around round-the-clock operations, with phased work or off-peak hours to keep goods moving.
Goods category, storage height and racking type.
Sprinklers within racking where heights require it.
Tanks and pump sets sized to the design.
Mist for offices, plant rooms and charging areas.
Which standard applies depends on the system, the building and, often, your insurer.
Automatic sprinkler design, including storage categories and in-rack protection.
Insurer sprinkler rules, widely specified for warehouses.
Building Regulations guidance, including compartment sizes for storage buildings.
Design framework for water mist systems in ancillary areas.
Fire safety in the design, management and use of buildings.
This page explains typical requirements. It isn't a fire strategy or design specification.
UK designed and built
Water mist and sprinkler systems
Send drawings and the fire strategy. We'll confirm the likely system and design standard.
Layouts, hydraulic calculations and documents for your insurer and Building Control.
Planned around your build programme or operating hours.
Testing, handover pack and a maintenance plan from day one.
Commercial systems need an annual service, plus the routine owner checks the design standard sets. We test pumps and valves, check heads and nozzles for damage and obstruction, and provide the service records insurers expect. We also maintain systems installed by other contractors.
Service & maintenance plans →Most projects are quoted after a drawing review.
Read our cost guide →Large ones often do. Approved Document B limits unsprinklered single-storey storage compartments to 20,000 m² in buildings under 18m, and insurers frequently require sprinklers whatever the size, commonly to LPC Rules.
It depends on your storage height, the goods stored and the racking. Above certain heights, roof-level sprinklers alone can't reach a fire in the racking, so sprinklers are fitted within the racks. We'll confirm after a survey.
Mist suits parts of a warehouse such as offices, plant rooms and battery charging areas. High-piled racked storage is normally protected with sprinklers to BS EN 12845 or LPC Rules.
Yes. We plan installation around your operations, with phased work or off-peak hours to keep goods moving.
Yes. We offer a full service including design, installation, commissioning, scheduled maintenance, compliance checks, and emergency support.
Yes. We can inspect, upgrade, and maintain existing mist or sprinkler systems to bring them in line with current regulations and performance expectations.
Our commercial water mist systems are designed to BS EN 14972-1, and our commercial sprinkler systems to BS EN 12845.
For residential projects, our sprinklers are designed to BS 9251. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. We also work to project and insurer requirements.
We assess your fire strategy, occupancy type, building design, and water supply. Based on this, we may recommend high-pressure mist, low-pressure mist, wet or dry sprinkler systems, or a hybrid approach.
We recommend annual servicing in line with BS 9251, BS EN 14972-1 or BS EN 12845, depending on the system type. In high-risk or heavily used environments, more frequent checks may be required.
Yes. SmartMist offers both advanced water mist systems and traditional commercial sprinkler systems. We recommend the most suitable option based on your building’s fire strategy, layout, risk profile, and water supply.
Yes, fire sprinkler systems can be retrofitted into most commercial buildings. However, factors such as ceiling space, water supply, and pipe routing must be considered. Retrofitting is often recommended for older buildings, hotels, offices, and apartment blocks to enhance fire safety without major structural changes.
Send what you have. These help us quote faster:
Or call 0330 113 5900