Residential Fire Suppression


Announcement
Our SmartMist DOME™ residential water mist system has met the performance criteria of BS EN 14972-17:2025 open room fire testing (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.

Key takeaways
SmartMist Systems' DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. The system is also designed to BS EN 14972-1, the European standard for the design, installation, inspection and maintenance of water mist systems.
The FPA confirmed the result to us in November 2026. The full written test report is being finalised; we will publish its reference and test dates here when it is issued.
For anyone specifying fire suppression for homes, flats, HMOs, care homes or small hotels, this matters. BS EN 14972-17 is now the standard residential water mist is tested against in the UK, and our system met the performance criteria of its open room fire test, independently and at full scale, while running at a reduced operating water flow.
BS EN 14972-17:2025 is the European fire test protocol for water mist systems in residential occupancies. BSI published it in July 2025. It sets out full-scale fire tests for water mist systems used to protect residential buildings with ceiling heights up to 5.5m.
The scope covers the places people live and sleep, including:
The tests are designed to show that a system controls a fire and keeps conditions survivable long enough for people to escape. Each test has set performance criteria, and a test report states which tests a system met and at what room height.
Until 2025, residential water mist in the UK was tested to BS 8458:2015. BSI withdrew BS 8458 in July 2025 and replaced it with BS EN 14972-17, bringing the UK into line with a single European test method.
That gives Building Control, fire engineers, insurers and warranty providers one consistent benchmark to check a system against. It also means specifiers should now ask for evidence of BS EN 14972-17 testing when they choose a residential water mist system.
Where a system is tested is as important as what it is tested to. The FPA's fire test laboratory is UKAS-accredited. UKAS (the United Kingdom Accreditation Service) is the national body that checks test laboratories are competent and impartial.
For a specifier, that means the result comes from an independent, accredited laboratory, not from the manufacturer's own testing.
Passing a fire test proves the system works in the test room. BS EN 14972-1 covers what happens next: how a water mist system is designed, installed, inspected and maintained on a real project.
Every SmartMist installation is designed to BS EN 14972-1, so the design and installation approach behind it is held to the same European framework as the fire testing.
If you are a homeowner, developer, landlord, architect or care home operator, here is what to check when you choose a residential water mist system:
For our SmartMist DOME™ residential water mist system we can answer the first three, and we agree the last three with you and your project team before design starts.
Our residential water mist systems protect a wide range of homes and residential buildings, including loft conversions, flats and apartments, HMOs, care homes and new build developments.
Water mist uses a fraction of the water of a traditional sprinkler, so there is less water damage after activation, and smaller systems can often run from the mains without a large tank.
No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.
It sets the full-scale fire tests for water mist systems in residential occupancies with ceiling heights up to 5.5m, including houses, flats, HMOs, care homes, bed and breakfasts, small hotels, hostels and hotel bedrooms and corridors.
The Fire Protection Association (FPA), a UKAS-accredited fire test laboratory.
BS EN 14972-17 is the fire test that proves a residential water mist system works. BS EN 14972-1 covers how water mist systems are designed, installed, inspected and maintained.
Keep it serviced as planned. If you are altering or extending the building, speak to us and your fire risk assessor or Building Control before work starts.
If you are planning a residential project and need fire suppression that is independently tested to the latest standard, get a free quote or call us on 0330 113 5900. You can also read more in our FAQs.
About the author
SmartMist Technical Team
Water mist and fire sprinkler specialists
SmartMist Systems Ltd designs, installs and maintains water mist and fire sprinkler systems for homes and commercial buildings across England, Scotland and Wales. Its SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the FPA.
Our accreditations and test evidence →Keep reading
Talk to a specialist
Send us your drawings or tell us about the project. We will recommend water mist, sprinklers or a combination, and explain the standards that apply.