Residential fire suppression

Tower Block Fire Suppression Systems

Sprinkler and water mist systems for high-rise residential blocks, from new builds to occupied retrofits. Designed with your fire engineer, installed flat by flat, and maintained for the life of the building.

✓ Water mist & sprinklers
✓ Design to commissioning
✓ UK-wide installation
Tower Block Fire Suppression Systems

Fire tested to BS EN 14972-17:2025, the new UK standard for home water mist

Our residential water mist system has passed full-scale fire tests to BS EN 14972-17 at the FPA, a UKAS-accredited test house, making us one of the first UK companies to do so. It’s the standard that replaced BS 8458, which gives Building Control and approved inspectors confidence in your fire strategy.

Open-plan fire safety without the fire doors

Keep your open-plan kitchen, loft conversion or living space. Discreet DOME water mist nozzles provide an approved alternative to protected escape routes and can reduce the need for fire doors, subject to Building Control.

80% less water than a domestic sprinkler system

Our DOME Gen 2 nozzle uses around 8 litres per minute, compared with 45 to 60 for a typical sprinkler head. That means less water damage, smaller pipework, and in most homes no water storage tank.

British-designed, made and installed, with Building Control support

We design, manufacture, install and maintain every home water mist system in-house. Our compliance team works directly with Building Control to help get your project signed off.

OverviewRisk factorsRegulationsMist or sprinklerDesignStandardsProjectMaintenance & costFAQsEnquire
Residential fire protection

Fire protection for high-rise living

In a tower block, a fire in one flat can put every resident above it at risk. Suppression controls the fire where it starts, limits smoke in shared escape routes and gives the fire service time to work.

SmartMist designs, installs and maintains water mist and sprinkler systems for apartment and tower blocks across the UK. We work with developers, architects and fire engineers on new buildings, and with landlords and managing agents on retrofits in occupied blocks.

  • Individual flats, communal areas and escape routes
  • New builds, conversions and occupied retrofits
  • Water mist, sprinklers or a combination
See all residential fire suppression →
Fire protection for high-rise living
What shapes the design

What shapes fire protection in a tower block

Two homes with the same floor area can need very different systems. These are the factors we look at first.

Building height

In England, new blocks of flats with a storey 11m or more above ground need sprinklers throughout. Blocks of 18m or 7 storeys and above are higher-risk buildings under the Building Safety Act.

Stay put or evacuate

Most blocks rely on residents staying in their flat unless the fire is in it. Suppression supports that strategy by controlling fires early.

Water supply

Tall buildings often need a tank and pump set. Low-flow water mist can reduce tank size and plant space.

Occupied buildings

Retrofits happen around residents. Small-bore pipework and flat-by-flat programmes keep disruption down.

Communal areas

Corridors, lobbies and bin stores need protecting as well as flats, and may need different heads or zoning.

Golden thread

Higher-risk buildings need accurate, up-to-date records of the system, from design through every service.

Requirements

Do tower blocks need sprinklers?

New blocks of flats in England with a storey 11m or more above ground need sprinklers throughout. In Scotland and Wales, all new flats need automatic fire suppression, whatever the height.

England

Approved Document B

New blocks of flats with a top storey 11m or more above ground should have sprinklers throughout, in every flat.

Higher-risk buildings

Building Safety Act 2022

Blocks of 18m or 7 storeys and above need Building Safety Regulator approval before work starts, and a golden thread of information.

Scotland & Wales

Devolved rules

Scotland requires fire suppression in all new flats. Wales has required sprinklers in all new and converted homes since 2016.

Choosing a system

Water mist or fire sprinklers?

We install both, so we recommend whichever meets your design standard with the least water and disruption.

Water mist

Less water, often no tank

Water mist uses a fraction of the water of a sprinkler, which can mean a smaller tank, less plant space and less damage to the flats below. Small-bore pipework is easier to route in occupied blocks, and options include individual pump units per flat or a whole-building system.

Explore residential water mist →
Fire sprinklers

The established, widely specified route

Residential sprinklers to BS 9251 are the established route for tall blocks, and the one many fire strategies specify. We design and install them for new buildings, and retrofit them into existing blocks with a tank and pump set where the mains can't supply the flow.

Explore residential sprinklers →
Mist and sprinklers aren't interchangeable in every building. We confirm the design standard with Building Control and your fire engineer before design, then recommend the system that meets it.
Design & installation

Designed with the building, installed around residents

Tower block systems are designed with the fire strategy, not around it. We agree head layouts, water supply and zoning with your fire engineer, architect and Building Control, and provide the documents higher-risk building approvals need.

For occupied blocks we plan the work flat by flat, keep residents informed and leave each home tidy at the end of the day.

Send your drawings

Flats & communal areas

Coverage for flats, corridors, lobbies and bin stores.

Tanks & pumps

Tank and pump sets sized to the building's demand.

Zoning & monitoring

Zone valves and links to the fire alarm and building management.

Records

Design and service records for the golden thread.

Standards & compliance

Standards for tower block fire suppression

Which standard applies depends on the system, the building and, often, Building Control.

Standard
Relevance
Status

Approved Document B

Sprinklers throughout new blocks of flats with a storey 11m or more above ground.

Current

BS 9251:2021

Code of practice for sprinkler systems in domestic and residential occupancies.

Current

BS 9991:2024

Fire safety in the design, management and use of residential buildings.

Current

BS EN 14972-1

The European standard for water mist design, installation, inspection and maintenance. Every SmartMist water mist installation is designed to it.

Designed to

BS EN 14972-17:2025

The European fire test standard for residential water mist. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17 open room fire test (3.5 m room height) at the FPA, a UKAS-accredited fire test laboratory.

Tested

BS 8458:2015

The former UK residential water mist standard, withdrawn by BSI in July 2025 and replaced by BS EN 14972-17.

Withdrawn

Building Safety Act 2022

Regulator approval and golden thread for blocks of 18m or 7 storeys and above.

Current

This page explains typical requirements. It isn't a fire strategy or design specification.

Certification & accreditation

ISO 9001:2015
Quality management
SafeContractor
Health and safety accreditation

Tested to BS EN 14972-17:2025 at the FPA

Our SmartMist DOME™ residential water mist system met the performance criteria of the open room fire test (3.5 m room height) at the FPA's UKAS-accredited fire test laboratory. Every installation is designed to BS EN 14972-1.

See all our accreditations →

Recent Clients

7-Storey Apartment Block Conversion, Water Mist Suppression, Norwich, UK
Project example

7-Storey Apartment Block Conversion, Water Mist Suppression, Norwich, UK

Apartment Block Conversion, Norwich

Client: Private Investment Company

Location: Norwich, UK

Project Duration: 18 months (First Fix to Commissioning)

Team on Site: Dedicated Project Manager on-site for 4 months

How we work

From drawings to handover

01

Review

Send drawings and the fire strategy. We'll confirm the likely system and design standard.

02

Design

Layouts, hydraulic calculations and documents for Building Control and your warranty provider.

03

Install

Planned around your build programme or residents.

04

Commission

Testing, handover pack and a maintenance plan from day one.

Aftercare

Servicing, including systems we didn't install

Residential systems need an annual service, plus the simple owner checks the design standard sets. We check pumps, valves and heads, and keep the records Building Control, landlords and insurers expect. We also maintain systems installed by other contractors.

Service & maintenance plans →
Cost

What affects the price

  • Height and number of flats: sets head count, zoning and water demand
  • Mist or sprinkler: changes tank, pump and pipe size
  • New build or retrofit: occupied blocks need phased work
  • Communal areas: corridors, lobbies and stores add zones
  • Water supply: tank and pump set if the mains can't supply the flow
  • Records and approvals: higher-risk building documentation

Most projects are quoted after a drawing review.

Read our cost guide →
Guides

Regulations and guidance

FAQs

Tower block fire suppression FAQs

Do tower blocks need sprinklers?

New blocks of flats in England with a storey 11m or more above ground need sprinklers throughout, under Approved Document B. In Scotland and Wales, all new flats need automatic fire suppression whatever the height. For existing blocks, a retrofit is usually driven by the fire risk assessment or fire strategy.

Can water mist be used instead of sprinklers in a tower block?

Often, yes, but it depends on the fire strategy. Water mist can meet the same objectives with far less water, and Building Control and fire engineers increasingly accept it. We confirm the design standard with them before design starts.

Can you retrofit a system while residents live in the block?

Yes. We work flat by flat, using small-bore pipework where we can, and plan access with your managing agent so each home is left tidy at the end of the day.

Does a higher-risk building need anything extra?

Blocks of 18m or 7 storeys and above need Building Safety Regulator approval before work starts, and accurate records of the system for the golden thread. We provide design and service records in a format that supports this.

Is BS 8458 still current for water mist systems?

No. BSI withdrew BS 8458:2015 in July 2025 and replaced it with BS EN 14972-17, the European fire test standard for residential water mist.

Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory, and every installation is designed to BS EN 14972-1. If you have an existing system, keep it serviced and speak to us before any alterations or extensions.

Are SmartMist residential water mist systems independently tested?

Yes. Our SmartMist DOME™ residential water mist system has met the performance criteria of the BS EN 14972-17:2025 open room fire test (3.5 m room height) at the Fire Protection Association (FPA), a UKAS-accredited fire test laboratory. Every installation is also designed to BS EN 14972-1, the European standard for water mist design, installation, inspection and maintenance.

BS EN 14972-17 replaced the previous UK residential water mist standard, BS 8458, which BSI withdrew in July 2025. See our full fire test and certification record.

Will all the nozzles activate in my property in the event of a fire?

No, that is a myth. Only the nozzle where the frangible bulb breaks will be activated, in the unfortunate event of a fire.

Does smoke caused by burning food trigger the water mist nozzle?

No. Smoke does not trigger the nozzle. The bulb inside each nozzle only breaks with direct heat from a fire, at 57°C (135°F).

A nozzle near an oven won't be set off by opening the oven door, because the heat disperses quickly into the room.

Are misting fire suppression systems safe for electronics and furniture?

Yes, misting systems use fine water droplets that reduce fire damage without excessive water exposure, making them safe for electronics and furniture.

Get a quote

Have a project in mind?

Send what you have. These help us quote faster:

  1. Floor plans and sections
  2. Building height and number of storeys
  3. Number of flats
  4. New build, conversion or occupied
  5. Fire strategy, if you have one
  6. Water supply and plant space
  7. Programme or Gateway dates
  8. Managing agent or landlord contact

Or call 0330 113 5900